期刊文献+

换热器紧固螺栓的应力腐蚀断裂分析 被引量:8

STRESS CORROSION FAILURE ANALYSIS OF THE FASTENING BOLT AT HEAT EXCHANGER
在线阅读 下载PDF
导出
摘要 紧固螺栓服役2年后发生成批断裂。采用宏观观察、化学成分分析、金相检验和扫描电镜与能谱分析等方法对失效螺栓进行了分析。结果表明,由于紧固螺栓长期浸在含有H2S介质的油料中,并在所承受的各种应力下又与腐蚀环境相互作用便产生了应力腐蚀,加上螺栓材质选用不当和硬度、显微组织不合理等其他因素,最终导致螺栓断裂。 The failure analysis of the bolts was made by macrostructure, chemical composieion, microstructure, fractography and EDS analysis. The results show that the stress corrosion, which is due to the interactions between the stresses and corrosion media , make the bolts fracture. All of the fastening bolts fracture after used two years, as the bolts was long-term immcrsed in oil which contains the H2S. In addition, inproper material compositions, hardness, and microstructure also result in the fracture of the bolts.
出处 《理化检验(物理分册)》 CAS 2007年第1期40-42,共3页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 螺栓 断裂失效 断口 应力腐蚀 Fastening bolt Fracture failure Fracture Stress corrosion