摘要
介绍了某无基载主机冰蓄冷系统方案,提出了优化设计方案。从系统经济性方面将两种方案与常规空调系统进行了比较,指出在冰蓄冷系统设计中应合理匹配基载主机与蓄冰主机,优化系统的经济性。
Presents the ice storage system scheme without refrigerating unit for base load, and represents an optimized design scheme. Compares the two schemes with traditional air conditioning system from the economic aspect, and recommends that the ice storage unit and the refrigerating unit for base load be properly matched to improve the system economics.
出处
《暖通空调》
北大核心
2007年第5期93-96,共4页
Heating Ventilating & Air Conditioning
关键词
冰蓄冷空调系统
基载主机
蓄冰
优化
ice storage air conditioning system, refrigerating unit for base load, ice storage, optimization