摘要 根据IEC17025-2005《测试和校准实验室能力的一般要求》的规定,测试报告必须包括评估测量不确定度的相关信息。按照JJF1059-1999《测量不确定度评定与表示》的方法,本文建立了数学模型、分析不确定度,得出了球压试验不确定度的评定过程,同时讨论了对球压试验结果影响较大的一些因素,分析了影响结果的主要因素和如何避免出现误差的方法。 According to the requirements of the IEC17025-2005 "The General Requirements for the Competence of Testing and Calibration Laboratories" , the test report must be included the information of evaluation of uncertainty in measurement. In the light of the standard ofJJF 1059 -1999 "Evaluation and Expression of Uncertainty in Measurement", this paper gives the method of establishing mathematic model and analyzing the uncertainty, obtains the process of evaluation of uncertainty in ball -pressure test measurement, discusses the diathesis that can effect the result, points out the way how to avoid mistake.
出处 《环境技术》 2007年第2期18-19,27,共3页 Environmental Technology
关键词 测量不确定度 球压试验 评定 误差 Uncertainty, Ball -pressure Test, Evaluation
  • 相关文献

参考文献4

  • 1国家质量技术监督局.JJF1059—1999.测量不确定度评定与表示.北京:中国计量出版社.1999
  • 2中国实验室国家认可委员会.CNAL/AC01:2005检测和校准实验室能力认可准则.北京:中国计量出版社,2005
  • 3国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.62-124.
  • 4IEC 60695-10-2:2003着火危险试验非正常热球压试验

共引文献65

同被引文献23

  • 1王忠义.球压试验[J].安全与电磁兼容,2005(1):75-76. 被引量:3
  • 2王莹,廖俊必,季立江,李代生.基于图像分割技术的压痕直径图像测量[J].兵工自动化,2007,26(2):72-73. 被引量:4
  • 3陈凌峰,刘群兴,罗宗敏.球压试验压痕判定方法[J].安全与电磁兼容,2006(6):62-62. 被引量:7
  • 4GB/T5169.21-2006,电工电子产品着火危险试验第21部分:非正常热球压试验[S].2006.
  • 5白福忠,高晓娟,包晓艳.布氏硬度的图像测量法[J].激光与红外,2007,37(11):1230-1233. 被引量:6
  • 6GBl4711-2013,中小型旋转电机通用安全要求[S].
  • 7CNAS-CL07:2011《测量不确定度要求》.
  • 8ISO/IEC 17025:2005 Accreditation Criteria for Testing and Calibration Laboratories.
  • 9IEC60695-10-2:2003着火危险试验.第10部分:将火中电工产品不正常热的效应减至最小的指南和试验方法.第2节:使用球压试验的非金属材料制成的产品的耐热性试验方法.
  • 10国家质量监督检验检疫总局.JJF1059.1-2012测量不确定度的评定与表示.北京:中国计量出版社.2012.