期刊文献+

凝结水精处理高速阳床氨化运行探讨 被引量:1

Research on Ammoniated Operation of High Speed Cation Exchanger for Condensate Fine Treatment
在线阅读 下载PDF
导出
摘要 通过分析凝结水精处理高速阳床氨化运行的原理,查找榆社电厂高速阴床漏氯和炉水电导率升高的原因,明确了阳床氨化运行的必要性,并提出了改进串联式高速阳、阴床出水水质的措施。 Based on the analysis of ammoniated operation principle of high speed cation exchanger for condensate fine treatment, and research of the cause for chlorine leakage and increase of boiler water conductivity,cation exchanger ammoniated operation is proved to be necessary. Some measures for improving water quality of series cation and anion exchangers were put forward.
出处 《华北电力技术》 CAS 2007年第A01期98-99,104,共3页 North China Electric Power
关键词 空冷 高速阳床 氨化运行 漏氯 再生 air cooling high speed cation exchanger ammoniated operation chlorine leakage renewable