期刊文献+

基于低温辐射计的红外辐射定标方法 被引量:2

Calibration of Infrared Radiation Based on Cryogenic Radiometer
原文传递
导出
摘要 在比较国际上基于低温辐射计的红外辐射定标技术的基础上,提出了以红外光源结合单色仪为辐射源,及以腔式热电堆探测器和低温辐射计为标准探测器的红外辐射定标方案。介绍了其结构和工作原理并给出了初步的定标结果。 After comparing different infrared calibration methods based on cryogenic radiometer, We propose an infrared calibration method based on cryogenic radiometer using infrared source in combination with a monochromator as radiation source,cavity thermopiles detector and cryogenic radiometer as primary standard detectors. We present the working principle and a schematic description of the new facility. A status report is also given on the development of this facility.
出处 《激光与光电子学进展》 CSCD 北大核心 2007年第4期62-67,共6页 Laser & Optoelectronics Progress
关键词 红外辐射定标 低温辐射计 腔式热电堆探测器 单色仪 infrared radiometric calibration cryogenic radiometer cavity thermopiles detector monochromator
  • 相关文献

参考文献13

二级参考文献26

  • 1李双,吴浩宇,李照洲,王骥,章骏平,郑小兵.近红外高精度光辐射标准探测器的实验研究[J].光学技术,2004,30(4):498-501. 被引量:13
  • 2李双,王骥,章骏平,吴浩宇,郑小兵.可见-近红外(488~944nm)基于低温辐射计的高精度光辐射绝对定标研究[J].光学学报,2005,25(5):609-613. 被引量:17
  • 3[2]Quinn T J,Martin J E.Cryogenic Radiometry,prospects for further improvements in accuracy[J].Metrologia.1991,28(3):155-161.
  • 4[3]Hoyt C C,FoukaI P V.Cryogenic radiometers and their application to metrology[J].Metrologia.1991,28(3):163-167.
  • 5[4]Foukal P V,Kochling H,Miller P.Cryogenic absolute radiometer as laboratory irradiance standards.remote.sensing detector and Pyroheliometers[J].Appl Opt,1990,29(7):988-993.
  • 6[5]Fox N P.Trap detector and their properties[J].Metrologia,1991,28(3):197-202.
  • 7[6]Bruegge C J,Dural V G,Chrien N L,et al.Calibration plans for the multi-angle imaging spectmRadiometer(MISR)[J].Metmlogia,1993,30(4):213-221.
  • 8[9]Boivin L P.Properties of sphere radiometers suitable for high-accuracy cryogenic-radiometer-based calibrations in the near-infrared[J].Metmlogia,2000,37(4):273-278
  • 9[10]李双.基于低温辐射计的近红外高精度光辐射定标研究[D].中国科学院安徽光学精密机械研究所,2003.
  • 10[11]Taylor B N,Kuyatt C E.Guidelines for evaluating and expressingthe uncertainty of NIST measumment results[EB/OL].http://physica.nist.gov/puks/guidelmes.

共引文献77

同被引文献28

  • 1李宪圣,任建伟,张立国,万志,朱启海,赵贵军.大口径红外光电系统现场辐射定标装置的研制[J].光电子.激光,2006,17(2):175-178. 被引量:33
  • 2温姣娟,夏金安.固体板条激光器的半导体激光抽运结构[J].激光与光电子学进展,2007,44(4):44-49. 被引量:2
  • 3苏美开,倪国强,左眆.频率红移法用于激光二极管热阻测量[J].光电工程,2007,34(5):48-51. 被引量:5
  • 4罗丹,郭伟玲,徐晨,舒雄文,沈光地.半导体激光器结温测试研究[J].半导体光电,2007,28(2):183-186. 被引量:6
  • 5G I. Ryabtsev, A N Kuzmin, J A. Ges, et al.. Thermal properties of high-power In GaAs/A1GaAs laser diodes[J]. Journal of Applied Spectroscopy, 1995, 62(5): 900-902.
  • 6C C Lee, J Park. Temperature measurement of visible light-emitting diodes using nematic liquid crystal thermography with laser illumination[J]. IEEE Photonics Technology Letters, 2004, 16(7): 1706-1708.
  • 7H Y Ryu, K H Ha, J H Chae, et al.. Measurement of junction temperature in GaN-based laser diodes using voltage- temperature characteristics[J]. Applied Physics Letters, 2005, 87(9): 093506.
  • 8J H Han, S W Park. Theoretical and experimental study on junction temperature of packaged Fabry-Perot laser diode[J]. IEEE Transactions on Device & Materials Reliability, 2004, 4(2): 292-294.
  • 9Y Xi, E F Schubert. Junction-temperature measurement in GaN ultraviolet light-emitting diodes using diode forward voltage method[J]. Applied Physics Letters, 2004, 85(12): 2163-2165.
  • 10费翔,钱可元,罗毅.大功率LED结温测量及发光特性研究[J].光电子.激光,2008,19(3):289-292. 被引量:56