在国内复线电气化铁道牵引网运行的户内型分区所中,一次系统主接线有10余种。本文通过对几例典型方案的分析比较,以主接线简化、联锁简单可靠和方案经济实用为目的,提出一种适用于运行实践的主接线方案。
In terms of domestic indoor section posts of the electrified double-tracked railway traction network, there are more than 10 types of main electrical schemes for the primary system. This article is to grope a suitable main electrical scheme which is practical to us through analysis and comparison among several typical schemes, which purpose is to simplify the main electrical scheme and make the interlocking reliable and simple, the scheme practical and economical.