期刊文献+

移植肾肾动脉狭窄的超声造影定量研究 被引量:11

Quantitative study of contrast enhancement ultrasound on transplant renal artery stenosis
暂未订购
导出
摘要 目的探讨超声造影定量分析诊断移植肾肾动脉狭窄(TRAS)的临床价值。方法对8例彩色多普勒发现的TRAS(经DSA确诊)患者行移植肾超声造影定量分析,将其开始增强时间(BT)、达峰时间(PT)、上升支斜率(BPAS)、降支减半时间(HT)、峰值强度(PI)及曲线下面积(AUC)与20例正常移植肾比较。结果TRAS组移植肾皮质增强程度弱于正常组;BT(P<0.005)、PT(P<0.001)大于正常组,BPAS、HT、PI、AUC(P均<0.001)小于正常组(P<0.001)。结论移植肾超声造影定量分析是诊断TRAS的有效手段,具有广阔的临床应用前景。 Objective To explore the clinical value of quantitative analysis of contrast enhancement ultrasound in diagnosing transplant renal artery stenosis (TRAS). Methods Eight patients with TRAS (verified by DSA) were performed by contrast-enhanced ultrasound, and their materials were analyzed quantitatively. Each of time to beginning enhancing (BT), time to peak intensity (PT), base- to- peak ascending slope (BPAS), half time of descending (HT), peak intensity (PI)and area under curve (AUC) were compared respectively with those of 20 normal transplanted kidneys from volunteers. Results Cortex of transplanted kidneys with TRAS enhanced more weakly than that of normal ones; In TRAS group, BT( P 〈 0.005) and PT( P 〈 0. 001 ) were bigger than those in normal group; BPAS, HT ,PI and AUC(each P〈0.001) were smaller than those in normal group. Conclusion Quantitative analysis of contrast enhancement ultrasound is an effective way to diagnose TRAS,and it has a bright prospect in clinical application.
出处 《临床超声医学杂志》 2007年第4期202-204,共3页 Journal of Clinical Ultrasound in Medicine
基金 广东省科技攻关项目 基金编号:99M04909G
关键词 超声检查 造影剂 肾移植 狭窄 肾动脉 Ultrasonogpahy Contrast agent Renal transplantation Stenosis Renal artery
  • 相关文献

参考文献7

二级参考文献28

  • 1李卓,龚渭冰,刘红梅,崔忠林,黄红波,孙煦勇.经静脉声学造影法与彩色多谱勒法对移植肾急性排异反应诊断的对比研究[J].第一军医大学学报,2003,23(5):439-441. 被引量:9
  • 2李建初,张缙熙,周墨宽,程玉芳,姜玉新.彩色多普勒超声对肾动脉狭窄的评价[J].中华超声影像学杂志,1996,5(4):159-161. 被引量:30
  • 3[1]Fervenza FC,Lafayette RAA,Alfrey EJ,et al.Renal artery stenosis in kidney transplants[J].Am J Kidney Dis,1998,31(1):141-148.
  • 4[2]Halimi JM,Najjar AA,Buchler M,et al.Transplant renal artery stenosis:Potential role of ischemia/reperfusion injury and long-term outcome following angioplasty[J].J Urol,1999,161(1):28-32.
  • 5[3]Reinitz ER, Goldman MH,Sais J ,et al.Evaluation of transplant renal artery blood fowl by Doppler sound-spectrum analysis[J].Arch Surg,1983,118(4):415-418.
  • 6[4]Plainfosse MC,Calonge VM,Beyloune-Mainardi C,et al.Vascular complication in the adult kidney transplant recipient[J].J Clin Ultrasound,1992,20(8):517-520.
  • 7[5]Tiefenthaler M,Riedl-Huter C.Value of sonography in kidney transplantation[J].Acta Med Austriaca,2001,28(3):74-77.
  • 8[6]Leung DA,Hoffmann U,Pfammatter T,et al.Magnetic resonance angiography versus duplex sonography for diagnosing renovasular disease[J].Hypertension,1999,33(2):726-731.
  • 9Kuersten B, Murthy TH, Li P. Ultraharmonic myocardial contrast imaging: in vivo experimental and clinical data from a novel technique[J]. J Am Soc Echocardiogr, 2001, 14 (9): 910-916.
  • 10Victor M, Daniel D, Solange A. Myocardial regional blood flow: quantitative measurement by computer analysis of contrast enhanced echocardiographic images [J]. Ultrasound Med Biol,1993, 19 (8): 619-633.