摘要 利用光参量振荡技术产生2.2~3.97um的宽调谐窄线宽中红外相干辐射.采用该中红外光源和衰荡腔光谱技术建立了一痕量气体成分光谱检测系统,并使用该系统对混合气体中的甲醛成分进行TN量,得到了72×10^-9的检测灵敏度.整个光谱检测系统具有很好的光谱分辨率、选择性以及测量灵敏度,适用于大气中多种污染或温室效应气体成分的检测. Tunable narrow linewidth mid-infrared radiation(MIR) from 2.2 to 3.9 um was generated by an optical parameter oscillator(OPO). Base on the high quality MIR source, cavity ring-down spectroscopy (CRDS) technique was used for gas sensing. A sensitivity of 72 × 10^-9 was achieved when use the system to measure the trace H2CO in gas mixture. Experimental results indicated that the system had the ability and the potential for future multi-trace gas measurements.
出处 《浙江师范大学学报(自然科学版)》 CAS 2007年第1期11-15,共5页 Journal of Zhejiang Normal University:Natural Sciences
基金 美国自然科学基金资助项目(#CHE0196189) 浙江师范大学科研启动基金资助项目(ZC304006094)
关键词 光参量振荡 中红外激光 衰荡腔光谱 气体检测 OPO Mid-infrared CRDS gas sensing
  • 相关文献

参考文献12

  • 1O'Keefe A,Deacon D A G.Cavity ring-downoptical spectrometer for absorption measurements using pulsed laser sources[J].Review of Scientific Instruments,1988,59 (12):2544-2551.
  • 2Romanini D,Lehamann K K.Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six,seven,and eight stretching quanta[J].J Chem Phys,1993,99 (9):6287-6301.
  • 3Engeln R,Helden G V,Roij A J A V,et al.Cavity ring down spectroscopy on solid C60[J].J Chem Phys,1999,110 (5):2732-2733.
  • 4Brown S S,Wilson R W,Ravishankara A R.Absolute Intensities for Third and Fourth Overtone Absorptions in HNO3 and H2O2 Measured by Cavity Ring Down Spectroscopy[J].J Phys Chem A,2000,104(21):4976-4983.
  • 5Paldus B A,Harb C C,Spence T G,et al.Cavity ringdown spectroscopy using mid-infrared quantum-cascade lasers[J].Opt Lett,2000,25 (9):666-668.
  • 6Paul J B,Scherer J J,Okeefe A,et al.Cavity ringdown measures trace concentrations[J].Laser Focus World,1997,33 (3):71-75.
  • 7Ball S M,Povey I M,Norton E G,et al.Broadband cavity ringdown spectroscopy of the NO3 radical[J].Chem Phys Lett,2001,342 (1/2):113-120.
  • 8Brown S S,Stark H,Ciciora S J,et al.In-situ measurement of atmospheric NO3 and NO5 via cavity ring-down spectroscopy[J].Geophys Res Lett,2001,28 (17):3227-3230.
  • 9Zaicki P,Richard N Z.Cavity-ring down spectroscopy for quantitative absorption measurement[J].J Chem Phys,1995,102 (7):2707-2717.
  • 10Petrov K P,Curl R F,Tittel K F.Compact laser difference-frequency spectrometer for multi-component trace gas detection[J].Appl Phys,1998,B66(3):531-538.