摘要
针对珠海电厂1号、2号机组T23钢管出现爆管现象,对T23钢管的显微组织、力学性能、维氏硬度、抗蒸汽氧化性能进行了测试和分析,指出长期超高温运行是T23钢管爆管的主要原因,为此,提出相应的防范措施,对今后该种管材在超(超)临界机组的大范围应用提供参考和借鉴。
In view of the T23 property, Vickers hardness, steel tube bursting of Units I and 2 in Zhuhai Power Station, the microstructure, mechanical anti-steam-oxidation performance of T23 steel tubes are tested and analyzed. It is concluded that the long-term superhigh temperature operation is the main cause of the tube bursting. Corresponding countermeasures are put forward to provide reference for large-scale application of T23 steel tubes to (ultra) supercritical units.
出处
《广东电力》
2007年第2期44-47,共4页
Guangdong Electric Power
关键词
T23钢管
爆管
显微组织
力学性能
金相分析
T23 steel tube
tube bursting
microstructure
mechanical property
metallographic examination