期刊文献+

切开复位单边外固定架固定治疗胫骨干骨折 被引量:1

Clinical Application in Closed Fracture of Tibia Diaphysis Treated by Operating Replacement to Fix with Unilateral External Fixation Apparatus
暂未订购
导出
摘要 目的探讨单边外固定架固定治疗闭合性胫骨干骨折时采用切开复位的临床效果。方法选择120例胫骨干闭合性骨折的患者,在条件尽可能相近的情况下分为两组,每组60例,一组采用切开复位,另一组采用闭合复位,复位后两组均使用单边外固定架固定。术后随访一年半。对其复位情况、骨折愈合情况、钉道及局部感染以及手术所用时间进行分析,并做统计学处理。结果切开复位组的解剖复位率明显高于闭合复位组(P<0.01),骨折愈合两组无统计学上的差异(P>0.05),钉道及局部感染情况两组相似,切开复位平均所用时间较闭合复位短。结论在使用单边外固定架固定治疗胫骨干闭合骨折时采用切开复位是一种很好的方法。 Objective To discuss the clinical effect of operating replacement to fix when treating closed fracture of tibia diaphysis with unilateral external fixation apparatus(UEFA). Methods Divide 120 cases of closed fracture of tibia diaphysis into two groups under the same possible circumstances. Each group has 60 cases. One group was treated by operating replacement, the other group was treated by closed replacement. Two groups were treated by unilateral external fixation apparatus to fix after replacement. The cases were interviewed for one year and a half after operations. To analyse their replacement, fracture union, partial infection in nail path and operation's time and to handle them in statistics. Results The dissection replacement of the operation replacement group was clearly higher than the closed replacement group(P〈0.01). There was no difference between two groups in statistics(P〉0. 05). Two groups were similar in nail path and partial infection. The average time which spent in operating replacement was shorter than closing replacement. Conclusion It is a very good way to treat closed fracture of tibia diaphysis by operating replacement to fix with Unilateral External Fixation Apparatps.
出处 《实用骨科杂志》 2007年第2期67-69,共3页 Journal of Practical Orthopaedics
关键词 胫骨干骨折 切开复位 单边外固定架 fracture of tibia diaphysis operating reduction unilateral external fixation apparatus
  • 相关文献

参考文献9

二级参考文献27

  • 1侯树勋,李文峰,张伟佳,王富,王予彬,史亚民,章亚东,韦兴.单侧成角度股骨转子间骨折外固定器的设计和临床应用[J].中华骨科杂志,1996,16(10):620-626. 被引量:45
  • 2王亦璁 孟继懋 等.骨与关节损伤[M].北京:人民卫生出版社,1996.308.
  • 3Sarmiento A, Latta LL. Functional fractrue bracing. J Am Acad or thop Surg 1999 Jan,7(1):66-75.
  • 4Geller A,et al. Tension wire position for hybrid external fixation of the proximal tibia. Jorthop Trauma 2000 Sep-Oct, 14(7):502-4.
  • 5Reniger AR,et al. A simple technique for creating hybrid fixators using a modified AO single adjustable clamp. J Orthop Trauma 1997 Jan, 11(1) :54-6.
  • 6Moorcroft CI,et al. A device for impend reduction of t.
  • 7Duda GN, et al. Interfragmentary motion in tibial osteotomies stabilized with ring fixators. Clin Orthop 2002 Mar;(396): 163-72.
  • 8Prat J,et al. Load transmission through the callus site with external fixation systems: theoretical and experimental analysis. J Biomech 1994 Apr,27(4) :469-78.
  • 9Barquet A,et al. The dynamic ASIF-BM tubular external fixator in the treatment of open fractures of the shaft of the tibia. Injury 1992,23(7) :461-6.
  • 10Pugh KJ,et al. The biomechanbics of hybrid external fixation. J Orthop Trauma 1999 Jan,13(1) :20-6.

共引文献42

同被引文献3

  • 1BROWNER B D.The science and practice of intramedullary nailingand edition[]..1996
  • 2Johner R,Wruhs O.Classification of tibial shaft fractures and correlation with results after rigid internal fixation[].Clinical Orthopaedics.1983
  • 3詹伟彦,巫伟东,何开正,文永强,汪曾荣,黄醒中.组合式外固定架治疗胫腓骨多段粉碎性骨折[J].中华创伤骨科杂志,2003,5(2):112-114. 被引量:16

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部