Study on Technique of Surface Plasmon Resonance Imaging Sensing for Biomolecular Interaction

Study on Technique of Surface Plasmon Resonance Imaging Sensing for Biomolecular Interaction
在线阅读 下载PDF
导出
摘要 High resolution of surface plasmon resonance (SPR) detection is of vital importance.SPR biosensing system resolution is determined by intrinsic sensitivity of biochip and light signal acquisition system.In this article,different signal acquisition system resolutions on photodetector were analyzed based on light intensity and phase detection.Result shows that charge coupled device (CCD) with larger numbers of pixels is potential to achieve higher detection resolution.A 64 pixel line array CCD and a 12 bit ADC can achieve resolution of 10^(-7) refractive index unit (RIU).In array detection mode,increasing of detection throughput is at the cost of decreasing system resolution.Simulation analysis indicates that,if noise is taken into account,phase modulation methods are capable of providing better noise reduction performance than intensity methods. High resolution of surface plasmon resonance (SPR) detection is of vital importance. SPR biosensing system resolution is determined by intrinsic sensitivity of biochip and light signal acquisition system, In this article, different signal acquisition system resolutions on photodetector were analyzed based on light intensity and phase detection. Result shows that charge coupled device (CCD) with larger numbers of pixels is potential to achieve higher detection resolution. A 64 pixel line array CCD and a 12 bit ADC can achieve resolution of 10-7 refractive index unit (RIU). In array detection mode, increasing of detection throughput is at the cost of decreasing system resolution. Simulation analysis indicates that, if noise is taken into account, phase modulation methods are capable of providing better noise reduction performance than intensity methods.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期483-487,共5页 Rare Metal Materials and Engineering
关键词 SPR biosensing intensity detection phase detection RESOLUTION SFR biosensing intensity detection phase detection resolution
  • 相关文献

参考文献19

  • 1Lukosz W. Biosensors & Bioelectronics [J], 1991, 6:215.
  • 2Jiri H. Sensors and Actuators B [J], 1997, 41:207.
  • 3Jiri H. Sensors and Actuators B [J], 1997, 41:207.
  • 4Jong S Y et al. Biosensors and Bioelectronics[J], 2005, 20: 2189.
  • 5Yu X et al. Sensor and Actuators B [J], 2003, 91:285.
  • 6Johnston K S et al. Sensors and Actuators B [J], 1999, 54:80.
  • 7Tao N J et al. J Rev Scilnstru[J], 1999, 70:4656.
  • 8Zhang H Q et al. Rev Sci Instru[J], 2003, 74:150.
  • 9Morgan H et al. Appl Phys Lett[J], 1994, 64:1330.
  • 10Berger C E H et al.Greve J. Rev Sci Instru[J], 1994, 65:2829.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部