期刊文献+

超高压输电线路单端暂态量保护元件的频率特性分析 被引量:75

Single-Ended Transient-based Protection for EHV Transmission Lines Basic Theory
在线阅读 下载PDF
导出
摘要 为有效利用故障暂态量中含有的丰富故障信息,需要对其在输电系统上的传播特性进行深入的分析。为此从输电系统的频域模型着手,全面分析了输电线路、母线和阻波器的频率特性,指出母线对地等效电容和阻波器的阻抗显著地不等于线路的特性阻抗,由此提出“线路边界”的概念。通过对线路边界的透、反射系数的进一步分析发现:暂态信号的高频段(特别是阻塞频带)穿越线路边界时将大为衰减,而低频段(1-10kHz)儿乎不衰减;为弱化线路的传输影响而突出线路边界的作用,宜选用100kHz以下的信号分量。文中的分析结果对其他行波或暂态量的应用研究具有参考价值。 Study on characteristic of transmission system in detail is important to effectively use fault transient components, which contain abundant fault information. The paper applies frequency domain model of transmission system to analyze the frequency characteristics of transmission line, busbar and line trap. Then presents that the surge impedance of busbar capacitance and line trap is different from transmission line, and based on which proposes the concept 'line boundary'. Through discussing further the reflective and refractive coefficients of line boundary, the features of line boundary are as follows: the attenuation of high frequency band (especially in band of line trap) of transient components generated by fault through line boundary is obvious, whereas the low frequency band (1-10kHz) components are hardly influenced. Moreover, the transient components below 100kHz should be adopted in purpose of outstanding the line boundary and weakening the transmission influence of transmission line. The paper is significant for other traveling-wave or transient-based protection researches.
出处 《中国电机工程学报》 EI CSCD 北大核心 2007年第1期37-43,共7页 Proceedings of the CSEE
基金 国家自然科学基金项目(50277027)~~
关键词 电力系统 输电线路 母线 阻波器 频率特性 线路边界 单端暂态量保护 power system transmission lines busbar line trap frequency characteristic line boundary non-unit transient based protection
  • 相关文献

参考文献10

  • 1Chamia M, Liberman S. Ultra high speed relay for EHV/UHV transmission lines -- development, design and application[J]. IEEE on Power Apparatus and Systems, 1978, 97(6): 2104-2116.
  • 2Crossley P A, Mclaren P G. Distance protection based on travelling waves[J]. IEEE on Power Apparatus and Systems, 1983, 102(9):2971-2983.
  • 3Dong Xinzhou, Ge Yaozhong, He Jiali. Surge impedance relay[J]. IEEE Transactions on Power Delivery, 2005, 20(2): 1247-1256.
  • 4Johns A T, Aggatwal R K, Bo Z Q, Non-unit protection technique for EHV transmission systems based on fault-generated noise, part hsignal measurement [J]. IEE Proceedings on Generation Transmission and Distribution, 1994, 141(2): 137-140.
  • 5Johns AT, Aggarwal R K, Bo Z Q. Non-unit protection technique for EHV transmission systems based on fault-generated noise, part 2:signal processing [J]. IEE Proceedings on Generation Transmission and Distribution, 1994, 141(2): 141-147.
  • 6Bo Z Q. A new non-communication protection technique for transmission lines[J]. IEEE Transactions on Power Delivery, 1998,13(4): 1073-1078.
  • 7哈恒旭,张保会,吕志来.利用暂态电流的输电线路单端量保护新原理探讨[J].中国电机工程学报,2000,20(11):56-61. 被引量:85
  • 8DommelHW著 李永庄 林集明 曾昭华译.电力系统电磁暂态计算理论[M].北京:水利电力出版社,1991..
  • 9Canadian, American EMTP User Group[M]. Alternative transient program rule book. 1992.
  • 10覃剑,陈祥训,郑健超.行波在输电线上传播的色散研究[J].中国电机工程学报,1999,19(9):27-30. 被引量:134

二级参考文献12

  • 1薄志谦.新一代电力系统继电保护──暂态保护[J].电网技术,1996,20(3):34-36. 被引量:41
  • 2程正兴(译) (美)崔锦泰.小波分析导论[M].西安:西安交通大学出版社,1994..
  • 3唐勇,中国电机工程学报,1997年,17卷,4期,267页
  • 4肖东辉,电力系统自动化,1993年,17卷,8期,46页
  • 5李永庄(译),电力系统电磁暂态计算理论,1991年
  • 6葛耀中,高压输电线路高频保护,1987年
  • 7张冠生,电器学,1980年
  • 8葛耀中(译),第五届电力系统保护进展国际会议论文译文全集.上,89页
  • 9程正兴,小波分析算法与应用,1998年
  • 10程正兴(译),小波分析导论,1994年

共引文献287

同被引文献832

引证文献75

二级引证文献853

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部