摘要 目的探讨1.5T磁共振扫描仪对小鼠原位移植性肝癌模型扩散加权成像(DWI)显示能力及较佳b值选择。方法对22只小鼠原位移植性肝癌模型进行多b值DWI成像及T2WI成像。计算不同图像中肿瘤信噪比(SNR)、肿瘤与肝脏对比噪声比(CNR)及信号强度比(SIR)等数据,并进行统计学分析。结果DWI成像能显示T2WI所显示的所有肿瘤。DWI显示病灶范围与T2WI无统计学差异(F=0.048,P>0.05)。DWI图像中肿瘤SNR、肿瘤与肝脏CNR及SIR随b值升高而降低,均高于T2WI图像,与T2WI间有统计学差异(FSNR=58.012,FCNR=47.743,FSIR=12.353,各组P<0.05)。b值600s/mm2与900s/mm2间肿瘤SNR、肿瘤与肝脏CNR无统计学差异,其他各b值间肿瘤SNR、肿瘤与肝脏CNR均有统计学差异。b值300、600、900s/mm2间及300与2000s/mm2间肿瘤与肝脏SIR无统计学差异,其他各b值间肿瘤与肝脏SIR均有统计学差异。结论1.5T磁共振可以对小鼠原位移植性肝癌模型进行DWI成像,b=900s/mm2是DWI成像较佳b值。 Objective To investigate the techniques of MR diffusion weighted imaging for mice model with implanted liver tumor at 1.5T MR scanner and select the reasonable b value of DWI sequence. Methods Twenty-two mice models with implanted liver tumor were imaged by using DWI (b= 300,600,900, 2000 s/mm^2) and T2WI sequences at 1.5T MR scanner. The signal to noise ratio (SNR) of tumors, contrast to noise ratio (CNR) and signal intensity ratio (SIR) of tumors and normal liver were calculated and analyzed. Results On diffusion-weighted images, all the tumors of mice models appeared hyperintensity. The difference of tumor extension on DWI and T2WI was not statistically significant (F= 0. 048, P〉0.05). The SNR of tumors, the CNR, SIR of tumors and normal liver decreased with the ascending of b value, and were significantly higher than that in T2WI (FSNR =58. 012, PSNR〈0. 05; FCNR =47. 743, PCNR〈0. 05; FSIR =12. 353, PSIR〈 0. 05). There were no statistical differences of the SNR of tumors, the CNR of tumors and normal liver in DWI with b=600 and 900 s/mm^2 , and the differences existed in DWI with other b values. There were no statistical differences of the SIR of tumors and normal liver in DWI not only among b = 300, 600, 900 s/mm^2 , but also between b = 300 and 2000 s/mm^2 , and the differences of SIR existed in DWI with other b values. Conclusion The diffusion-weighted image of mice model with implantable liver tumor could be acquired at 1.5T MR scanner. 900 s/mm^2 is reasonable b value for DWI sequence.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第12期1777-1780,共4页 Chinese Journal of Medical Imaging Technology
关键词 肝肿瘤 磁共振成像 扩散加权成像 动物模型 B值 Liver neoplasms Magnetic resonance imaging Diffusion weighted imaging Animal model b value
  • 相关文献

参考文献2

二级参考文献10

  • 1[1]Schaefer PW, Grant PE, Gonzalez RG. Diffusion-weighted MR imaging of the brain[J]. Radiology, 2000, 217(2):331-345.
  • 2[2]Petrella JR, Provenzale JM. MR perfusion imaging of the brain: techniques and applieations[J]. Am J Roentgenol, 2000, 175(1):207-219.
  • 3[3]Wong JC, Provenzale JM, Petrella JR. Perfusion MR imaging of brain neoplasms[J] . Am J Roentgenol, 2000, 174(4) :1147-1157.
  • 4[4]Kim T, Murakami T, Takahashi S, et al. Diffusion-weighted singleshot echoplanar MR imaging for liver disease [J]. Am J Roentgenol,1999,173(2): 393-398.
  • 5[5]Materne R, Smith AM, Peeters F, et al. Assessment of hepatic perfusion parameters with dynamic MRI [J]. Magn Reson Med, 2002, 47(1) :135-142.
  • 6[6]Van Beers BE, Leconte I, Materne R, et al. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity[J]. Am J Roentgenol, 2001, 176(3):667-673.
  • 7[7]Keogan MT, Edelman RR. Technologic advances in abdominal MR imaging[J]. Radiology, 2001, 220(2):310-320.
  • 8[8]Goudemant JF, Van Beers BE, Demeure R, et al. Comparison of unenhanced and gadoxetate disodium-enhanced spin-echo magnetic resonance imaging for the detection of experimental hepatocellular carcinoma in the rat[J]. Invest Radiol, 1998, 33(2):80-84.
  • 9贾洪顺,全显跃,曾盛,温志波.兔VX2肝癌CT、MRI动态评价[J].第一军医大学学报,2002,22(2):141-144. 被引量:32
  • 10袁友红,肖恩华.肝脏磁共振扩散成像及进展[J].实用放射学杂志,2003,19(10):945-948. 被引量:10