摘要 目的评价动力加压髋螺钉(dynamichipserew,DHS)治疗股骨转子间骨折的临床效果。方法回顾性分析西充县人民医院1998-03/2005-06采用135°的DHS治疗股骨转子间骨折36例,平均年龄51岁。结果获得平均1·2年随访者35例。34例固定坚强骨折顺利愈合,平均愈合时间4·5个月,1例术后8月骨折骨性愈合,颈干角105°,髋活动轻度受限。结论DHS是手术治疗股骨转子间骨折较好的内固定器。
出处 《职业卫生与病伤》 2006年第4期300-301,共2页 Occupational Health and Damage
  • 相关文献

参考文献7

  • 1Jensen JS, Michaelsen M. Trochanteric femoral fractures treated with Mclaughlin osleosynthesis [ J ]. Acta Orthop Seand, 1975, 46:795 -803.
  • 2Evans EM. Trochanteric fractures [ J ]. J Bone Joint Surg(Br), 1951, 33: 192-204.
  • 3Lindsey RW, Teal P, Prlbe RA, et al. Early experience with the Gamma interlocking nail ror pertrochanteric fractures of the proximal femur [J]. J Trauma, 1991, 31: 1649-1658.
  • 4Adams CI, Robinson CM, Court - Brown CM, et al. Prospective randomized controlled trial or an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the the femur [J]. J Orthop Trarma, 2001, 15:394 -400.
  • 5Osnes EK, Lofthus CM, Fslch JA, et al. More postoperative femoral fractures with the Gamma nail than the sliding screw plate in the treatment of trochanteric fractures [ J ].Acta Orthop Scand, 2001, 6:252 -256.
  • 6Jacobs RR, Moclain O, Armstrong HJ. Internal fixation of intertrochanteric hip fratures; a clinical and biomechanical study [J]. Clin Orthop, 1980, (146) : 62-70.
  • 7朱锦宇,朱庆生,韩一生,吴尧平,刘建,李明全,袁志.老年不稳定型转子间骨折的内固定选择及术后并发症原因分析[J].中华创伤骨科杂志,2005,7(6):505-507. 被引量:46

二级参考文献9

  • 1Sadowski C, Lubbeke A, Saudan M, Riand N, Stem R,Hoffmeyer P. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a95 degrees screw-plate: a prospective, randomized study. J Bone Joint Surg(Am), 2002, 84: 372-381.
  • 2Haidukewych GJ, Israel TA, Berry DJ. Reverse obliquity fractures of the intertrochanteric region of the femur. J Bone Joint Surg(Am), 2001, 83: 643-650.
  • 3Kaufer H. Mechanics of the treatment of hip injuries. Clin Orthop, 1980, (146): 53-61.
  • 4Owens WD, Felts JA, Spitznagel EL Jr. ASA physical status classifications: a study of consistency of ratings. Anesthesiology,1978, 49: 239-243.
  • 5Audige L, Hanson B, Swiontkowski MF. Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices. Int Orthop, 2003, 27:197-203.
  • 6Leung KS, So WS, Shen WY, Hui PW. Gamma nails and dynamic hip screws for peritrochanteric fractures. A randomised prospective study in elderly patients. J Bone Joint Surg(Br),1992, 74: 345-351.
  • 7Bridle SH, Patel AD, Bircher M, Calvert PT. Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg(Br), 1991, 73: 330-334.
  • 8Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P,Bertens CL, Delince PE. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. J Bone Joint Surg(Am), 1998,80: 618-630.
  • 9李强,罗先正,王志义,吴杰,郭艾.人工髋关节置换术后评估方法的研究[J].中华骨科杂志,2001,21(12):721-725. 被引量:133