摘要
分析了原V型滤池配水系统(陶瓷滤砖)存在的布气不均匀等问题,制定了相应的整改方案,将陶瓷滤砖更换为塑料滤砖,并加强了施工期的质量控制和监管,达到了预期的改造效果。
Uneven air distribution and other problems existing in the water distribution system of the original V-type filter with ceramic tiles were analyzed. The appropriate reconstruction scheme of changing the ceramic tiles to the plastic tiles was established. The quality control and supervision of the construction were reinforced, and the expected reconstruction results were achieved.
出处
《中国给水排水》
CAS
CSCD
北大核心
2006年第24期27-29,共3页
China Water & Wastewater
关键词
V型滤池
配水系统
陶瓷滤砖
塑料滤砖
V-type filter
water distribution system
ceramic filter tiles
plastic filter tiles