摘要 目的:建立测定人血浆中美他环素质量浓度的高效液相色谱法。方法:以土霉素为内标,乙腈-0.05mol·L^-1磷酸二氧钾(30:70)为流动相,流速1.0mL·min^-1,柱温30℃,检测波长244nm,进样量20μL。结果:在0.134~5.373mg·L^-1浓度范围内,线性方程为Y=0.008765+0.068608C,r=0.9992。平均回收率为98.7%,日内RSD〈3,日间RSD〈25。结论:该法具有简单快速、灵敏特异、准确,适用于美他环素的血药质量浓度测定及药动学研究。 OBJECTIVE To establish an HPLC method for the determination of metacycline in human plasma. METHODS Oxytetracycline was used as the internal standard, and detected at 244 nm. The mobile phase consisted of acetonitrile-0. 05 mol·L^-1 potassium dihydrogen phosphate solution (30:70), flow rate was 1.0 mL·min^-1 ,the column temperature was 30℃ ,the injection volume was 20μL. RESULTS The calibration cures was linear in the range from 0. 134μg·mL^-1 to 5. 373μg·mL^-1 for metacycline (r = 0. 999 2). The relative standard deviations of the intra-day and inter-day were less than 5%. The mean ex traction recovery was 98%. CONCLUSION The method is simple, rapid, sensitive and accurate, which may be suitable for the determination of metacycline concentration in human plasma and pharmacokinetics studies.
作者 陈蓉 石凤鸣
出处 《中国医院药学杂志》 CAS CSCD 北大核心 2006年第12期1497-1498,共2页 Chinese Journal of Hospital Pharmacy
关键词 高效液相色谱法 美他环素 血药质量浓度 HPLC metacycline plasma drug concentration
  • 相关文献

参考文献5

  • 1Hane MR, Visser H, Koolwijk P,et al. Inhibition of MMP synthesis by doxycycllne and chemically modified tetracyclines(CMTs) in human endothelial cells[J]. Adv Dent Res, 1998,12(2):114.
  • 2顾炳仁,任雅明,朱瑞英.分光光度法测定盐酸甲稀土霉素及其制剂的含量[J].现代应用药学,1994,11(1):41-42. 被引量:6
  • 3Barary MH. Application of the computerized compensation method and the orthogortal functions method of correct for irrclevant interference in spectrofluorometry[J]. J Clin Pharm Ther,1991,16(6):443-451.
  • 4Naidong W, Verresen K, Roets E, et al. Determination of metacycline and related substances hy eolum liquid chromatography on poly (styrene-divinylbenzene) [J]. J Chromatogr, 1991,8(1):61-66.
  • 5Mack GD, Ashworth RB. A high performance liquid chromatographic system for the analysis of tetracycline drug standards,analogs,degradation products and other impurities[J]. Chromatogr Sci, 1978,16(3):93.

共引文献5

同被引文献2135

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部