摘要 用激光作为离子迁移谱(IMS)仪的电离源,研究了在大气压力下对痕量物质甲醛进行检测的方法。介绍了实验装置,讨论了迁移管两端电压、温度以及激光能量不同的条件下获得的离子信号强度(减去本底后的强度),得到了很有意义的实验结果。结果表明,该方法行之有效,并且得到了很高的探测灵敏度,检测极限达到了ppb量级。 An ion mobility spectrometer(IMS) equipped with a laser ionization source is used for the sensitive detection of formaldehyde wnder atmospheric pressure. Experimental apparatus is introduced. We also discussed the ion signal intensity of analyte wnder various drift voltages,different temperature and laser energy. Experimental results show that this method is very effective, and it has high sensitivity, Detection limits are determined to be in the upper ppb range.
出处 《光电子.激光》 EI CAS CSCD 北大核心 2006年第12期1507-1509,共3页 Journal of Optoelectronics·Laser
基金 曲阜师范大学科研启动基金资助
关键词 离子迁移谱(IMS) 迁移率 甲醛 分辨率 ion mobility spectrometry(IMS) mobility formaldehyde resolution
  • 相关文献

参考文献3

二级参考文献29

  • 1胡海红,戴修道.室内空气污染对健康的影响及控制[J].中国公共卫生,1996,12(1):13-14. 被引量:34
  • 2韩克勤,井海宁.室内化学品中挥发性有机化合物的挥发特征[J].卫生研究,1997,26(1):65-67. 被引量:12
  • 3Parker D H,Bernstein R B,Lichtin D A.Multiphoton ionization-fragmentation patterns of tertiary amines[J].J Chem Phys,1981,75(6):2577-2582.
  • 4CHOU Mau-song.Multiphoton ionization of methyl radicals in CH4 pyrolysis[J].Chem Phys Lett,1985,114(3):279-281.
  • 5Sapers S P,Donaldson D J.A REMPI investigation of methyl iodide Rydberg state predissociation[J].Chem Phys Lett,1990,173(2,3):257-264.
  • 6Zarndee L,Bernstein R B.Resonance-enhanced multiphoton ionization and fragmentation of molecular beams:NO,I2,benzene,and butadiene[J].J Chem Phys,1979,71(3):1359.
  • 7Boesl U.Laser mass spectrometry for environmental and industrial chemical trace analysis[J].J Mass Spectrom,2000,35(3):289-304.
  • 8Castaldi M J,Senkan S M.Real time,ultrasensitive monitoring of air toxics by laser photonionization time-of-flight mass spectrometry[J].J Air & Waste Mgmt.Assoc,1998,48:77-81.
  • 9Loepfe M,Burtscher H,Siegmann H C.Analysis of combustion products using time-of-flight mass spectrometry[J].Water Air and Soil Pollution,1993,68(1-2):177-184.
  • 10Franzen J,Frey R,Nagel H.Fast monitoring of motor exhaust components by resonant multiphoton ionization and time-of-flight mass spectrometry[J].J Mol Struct,1995,347:143-151.

共引文献71

同被引文献77

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部