介绍了采用E JA智能差压变送器测量锅炉汽包水位的方法,包括导压管路的敷设、变送器的安装、量程设定、零点迁移等安装和调试技巧。
This text introduces the method of measuring steam drum water level of boiler with EJA smart differ-pressure transmitter,including the installation and debugging technique of laying pipeline, the installation of transmitter, the enactment of span and moving zero ,etc.