期刊文献+

城市污水处理厂设计进水水质确定和出水水质评价 被引量:34

Influent quality estimation and effluent quality evaluation of municipal wastewater treatment plants
在线阅读 下载PDF
导出
摘要 以广州市各污水处理厂的进出水水质的实测数据为例,通过概率分析,进行了城市污水处理厂设计进水水质确定和出水水质评价的尝试。这些实测数据,经过适当变换,可以与标准正态分布曲线良好符合,说明它们基本遵从正态分布规律,并更加遵从对数正态分布规律。按照保证概率确定了该地区或类似地区的城市污水处理厂的设计进水水质,并利用达标概率评价了广州市各污水处理厂的出水水质。 In this paper, the test data of influent quality and effluent quality of municipal wastewater treatment plants in Guangzhou are analyzed by probability method to estimate the designed influent quality and to evaluate effluent quality. The test data transformed properly can be fitted well to normal distribution and better to logarithmic normal distribution. It is proved that the test data follow normal distribution rule approximatively and logarithmic normal distribution rule better. The designing influent quality is estimated according to the ensurence probability, and the effluent quality is evaluated by probability if meeting the standard.
作者 周克钊 周敉
出处 《给水排水》 CSCD 北大核心 2006年第9期26-30,共5页 Water & Wastewater Engineering
关键词 城市污水处理厂 进水水质 出水水质 实测数据 概率分析 广州市 Municipal wastewater treatment plant Influent quality Effluent quality Test data Probability analysis Guangzhou City
  • 相关文献

参考文献3

  • 1廖足良.采用HYBASTM工艺升级改造活性污泥工艺脱氮除磷.见:2005全国自来水厂污水处理厂技术改造研讨会论文集.杭州,2005
  • 2Merritt F S.工程技术常用数学.北京:科学出版社,1976
  • 3数学手册编写组.数学手册[M].北京:高等教育出版社,1984..

共引文献6

同被引文献205

引证文献34

二级引证文献179