期刊文献+

H_2O_2-鲁米诺-荧光素钠-K_2CO_3高灵敏化学发光法测定二氧化碳 被引量:3

Highly Sensitive Determination of Carbon Dioxide with H_2O_2-Luminol-Uranine-K_2CO_3 Chemiluminescent Reaction
在线阅读 下载PDF
导出
摘要 在碱性介质中,CO32-对H2O2氧化鲁米诺化学发光反应具有重要作用,荧光素钠对该反应具有很强的增敏作用.据此,建立了化学发光法测定二氧化碳的新方法.方法的线性范围为1.0×10-10~5.0×10-6mol?L-1CO32-,检出限为1.2×10-11mol?L-1CO32-(相当于5.3×10-10g?L-1CO2).该方法用于室内外空气中二氧化碳含量的测定,相对标准偏差1.8%~2.1%(n=11),加标实验回收率97.6%~101.4%.论文还探讨了反应的发光机理,发光反应很可能是由溶液中的CO32-与H2O2作用而产生的活性自由基引发,荧光素钠对发光的增敏作用为化学能量转移过程. The chemiluminescent (CL) reaction for the oxidation of luminol with hydrogen peroxide in an alkaline medium was greatly affected by the presence of carbonate. The intensity of CL reaction was evidently enhanced by the addition of uranine. Based on this, a novel CL method for the determination of carbon dioxide was established. The method provided the detection a wide linear concentration rang from 1.0 × 10^-11 to 5.0× 10^-6 mol·L^-1 and a low detection limit of 1.2× 10^-11 mol·L^-1 carbonate or 5.3× 10^-10 g·L^-1 carbon dioxide. It has been applied to determination of carbon dioxide in indoor and outdoor air with relative standard deviations (RSD) of 1.8%-2.1% (n= 11). The recoveries of the spiked samples were 97.6%- 101.4%. A reasonable mechanism was also proposed. The CL reaction is probably triggered by the interaction of H2O2-K2CO3 and then enhanced by uranine via chemical energy transfer from luminol to uranine.
出处 《化学学报》 SCIE CAS CSCD 北大核心 2006年第18期1876-1880,共5页 Acta Chimica Sinica
基金 国家自然科学基金(No.20437020) 中国科学院重要方向性研究(No.KZCX3-SW-432)资助项目.
关键词 化学发光 鲁米诺 荧光素钠 二氧化碳 chemiluminescence luminol uranine carbon dioxide
  • 相关文献

参考文献3

二级参考文献24

共引文献17

同被引文献23

  • 1王永宁,李荣秀,李成武,高云华,郭小英,顾忠泽.微粒子化学发光免疫测定促甲状腺素敏感性方法的建立与应用[J].细胞与分子免疫学杂志,2004,20(5):629-631. 被引量:3
  • 2何碧芬,于敬哲.化学发光免疫分析仪校准方法初探[J].计量与测试技术,2006,33(10):29-29. 被引量:3
  • 3BEAMAN J M, WOODHEAD J S. A simplified strategy for thyroid function [J]. Clin. Chem, 1989,35(5) : 828-830.
  • 4陶义训.免疫学和免疫学检测[M].北京:人民卫生出版社,i997.
  • 5光学仪器设计手册编辑组.光学仪器设计手册[M].北京:国防工业出版社,1971.535-536.
  • 6Rushton A, Ward A S , Holdich, R G. Solid-Liquid Filtration and Separation Technology (Second)[M]. New York, Wiley-VCH, 2000.35-59.
  • 7Kamidate T, Komatsu K, Tani H, et al. Direct determination of horseradish peroxidase encapsulated in liposomes by using luminol chemiluminescence [ J ]. Anal Sci,2008,24(4): 477-481.
  • 8Minekawa T, Ohkuma H, Abe K, et al. Development of ultra-high sensitivity bioluminescent enzyme immunoassay for hepatitis B virus surface antigen using firefly luciferase [J]. Luminescence, 2009,24(6): 394-399.
  • 9Kamidate T, Maruya M, Tani H, et al. Application of 4-iodophenol- enhanced luminol chemiluminescence to direct detection of horseradish peroxidase encapsulated in liposomes [ J ]. Anal Sci,.2009,25(9): 1 163-1 166.
  • 10Kolthoff I M, Lehmicke D J. Polarographic behavior of phenolphthalein[J ]. JAm Chem.Soc, 1948,70(5): 1 87%1 885.

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部