期刊文献+

脊波导TRL校准技术的研究 被引量:2

Study on TRL calibration method for double ridge waveguide
在线阅读 下载PDF
导出
摘要 本文首先讨论了矢量网路分析仪TRL校准技术对校准件的要求,并根据校准原理设计出了脊波导TRL校准件的尺寸。由于脊波导脊的重合性对校准件与测试端面连接处的反射具有较大影响,对校准件采用精确定位和表面抗氧化处理。最后利用网络分析仪的10项误差修正原理完成了脊波导的TRL校准,实现了脊波导器件微波参数的准确测试。 The design requirement of TRL calibration kit is discussed in this paper. The dimensions of the calibration kit for double ridge waveguide were designed according to calibration theory. Accurate alignment and surface anti-oxidation processing were applied to the calibration kit to reduce the influence of ridge mismatch. The TRL calibration was completed using 10 error correction models in the vector network analyzer. The accurate measurement of double ridge waveguide device was realized.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2006年第9期1041-1043,共3页 Chinese Journal of Scientific Instrument
关键词 TRL校准 脊波导 校准件 微波测量 TRL calibration double ridge waveguide calibration kit microwave measurement
  • 相关文献

参考文献5

  • 1PACKARD H. HP8510C network analysis operation and programming[Z]. Manual, 08510 90281, 1994.
  • 2陈国强,李琦,刘金亮.HP8510C非同轴系统TRL校准技术[J].微波学报,1998,14(3):238-243. 被引量:8
  • 3WU K, DING Y, FANG D. A parameter extraction technique for MM/FEM analysis of multilayered RF passives using TRL calibration[J]. IEEE Microwaveand Wireless Components, 2004, 14(9): 452-454.
  • 4KASTEN S K, STEER M B, POMERLEAU R. Enhanced through-reflect-line characterization of two-port measuring systems using free space capacitance calculation[J]. IEEE Trans. on Microwave Theory and Technology, 1990, 38(2): 215 217.
  • 5LI L, ZHU I.. Numerical TRL calibration technique for parameter extraction of planar integrated discontinuities in a deterministic MoM algorithm [J]. IEEE Microwave and Wireless Components, 2002, 12 (12):485-487.

二级参考文献1

  • 1董树义,近代微波测量技术,1995年