针对大容量直接空冷机组按照规定选用电动给水泵所伴生的问题,提出了按TRL工况选用电动给水泵的方法。此法节电效果巨大,就3台300MW直接空冷机组的电厂而言年节电约107kW h。
This article give a measure that selected electrical feedwater pump according to TRL working condition for great capacity air direct cooled ST sets. This measure have a great effect on energy saved that for 3 ×300MW air cooled ST sets, it Can be saved 10^7 kW · h one year.