本文介绍了制药企业高效过滤器DOP检漏的原理、检测方法、结果判定及处理、检漏周期等内容,并对DOP检漏及其标准间的差别的有关问题进行了探讨。
Introduces the principle, test procedure, acceptance criterion and frequency of DOP leak test for HEPA filter in pharmaceutical industry. The issues of DOP test and differences of standards are reviewed and commented.