期刊文献+

中值时间对脉冲MIG焊熔滴过渡过程的影响

EFFECTS OF MEDIAN TIME ON DROPLET TRANSFER PROCESS IN MIG WELDING
在线阅读 下载PDF
导出
摘要 对脉冲M IG焊而言,由于熔滴过渡过程是一个多干扰、强耦合、复杂的非线性过程,因此,很难对其进行有效的控制。设计了一种新的工艺方法:中值波形控制策略,即在满足一脉一滴的过渡形式下,通过波形控制来保证熔滴的大小一致,可有效控制熔滴过渡过程,焊接效果较好。实验结果表明:当中值电流为一理想值时,中值时间太短,中值阶段所起的作用非常小,达不到所设计的要求;中值时间过长,易产生短路过渡;中值时间为一理想值,焊接质量良好。 The droplet transfer process of pulsed metal inert-gas (M|G) welding is a multi-interferences, high-amplitude couple and complex non-linear process, so effective control on it is difficult. Control strategy of waveform with median phase is a new technique. Good appearance of weld is obtained by controlling the shape of waveform to make the droplets have the same size, on the basis of one droplet per one pulse. The experimental results shown when the median current is perfect, there is no droplet transfer when the median time is short, and there is short circuiting transfer when median time is long; there is good appearance of weld when median time is perfect.
出处 《焊接》 北大核心 2006年第8期18-21,共4页 Welding & Joining
基金 国家自然科学基金资助项目(50375054) 广东省科技攻关项目(2001A105010)
关键词 脉冲MIG焊 熔滴过渡 中值波形 pulsed metal inert-gas welding, droplet transfer, median phase waveform
  • 相关文献

参考文献6

  • 1Amin N. Pulsed current parameters for arc stability and controlled metal transfer in arc welding[ J]. Metal Construction,1983(5) : 272 -278.
  • 2Kim Y S, Eagar T. Metal transfer in pulsed current gas metal arc welding [ J ]. Welding Journal, 1993 ( 7 ) : 279s -287s.
  • 3Jacobsen N. Monopulse investigation of drop detachment in pulsed gas metal arc welding[ J]. Journal of Physics D: Applied Physics, 1992, 25:783 -797.
  • 4Amin M. Synergic pulse MIG welding [ J ]. Metal Construction, 1981, 13(6): 349-353.
  • 5刘会杰,张九海,白富平.脉冲MIG焊微机控制系统的研制[J].电焊机,1993,23(4):24-27. 被引量:3
  • 6赵举东,杨虹.脉冲MIG/MAG焊接熔滴过渡的双模糊器控制系统[J].电气自动化,1997,19(6):22-25. 被引量:2