摘要 目的比较3D-CEMRA和2D-TOFMRA对颅内静脉窦血栓的诊断价值。资料与方法8例经临床及影像学随访证实的颅内静脉窦血栓患者及8例健康志愿者分别行3D-CEMRA和2D-TOFMRA检查。由两名放射学医师共同回顾性阅片取得一致意见,病变组分别比较两种MRA技术单独应用MIP和MIP联合MPR、CPR及原始图像对血栓部位、血栓范围、窦腔闭塞及侧支静脉的检出率。对照组仅在MIP和原始图像上观察颅内静脉走行形态、信号强度。结果血栓共累及了20处颅内静脉窦,其中上矢状窦7处,窦汇区、左侧乙状窦及左侧横窦各2处,右侧横窦、右侧乙状窦各3处,右侧颈静脉球1处。在显示颅内静脉窦血栓范围、窦腔闭塞程度及侧支静脉方面,3D-CEMRA优于2D-TOFMRA(P值均<0.01)。3D-CEMRA采用MIP联合MPR、CPR及原始图像优于单独采用MIP(P值<0.01)。2D-TOFMRA采用MIP联合MPR、CPR及原始图像和单独采用MIP比较,二者并无明显差异(P值>0.01)。结论对颅内静脉窦血栓的评价,3D-CEMRA优于2D-TOFMRA,多种后处理技术的联合应用能更好显示血栓的范围、窦腔闭塞的程度和侧支静脉循环。 Objective To compare the diagnostic value of 2D-TOF MRA and 3D-CE MRA in the evaluation of intracranial dural sinus thrombosis. Materials and Methods 8 patients with dural sinuses thrombosis proved by clinical data and imaging follow up, 8 healthy volunteers were examined with 3D-CE MRA and 2D-TOF MRA. Two radiologists in consensus retrospectively compared the maximum intensity projection images (MIP), and combined with multiplanar reconstructed images (MPR), curved planar reconstructed images (CPR) and source images at 3D-CE MRA in patients with those obtained at 2D-TOF MRA. Visualization of the site and extent of thrombosis, degree of occlusion and collateral veins were recorded. The visualization of normal intracranial venous structures and intensity in control group were also recorded. Results Of 20 thrombosis in g patients, 7 were located in the superior sagittal sinus, 2 in the torcular Herophili, 2 in the left transverse sinus and sigmoid sinus respectively, 3 in the right tranavorae sinus and sigmoid sinus respectively, and 1 in the right jugular bulb. Overall, 3D CE MRA provided a superior visualization of the extent of thrombosis, degree of occlusion and collateral veins than do 2D-TOF MRA ( P 〈 0.01, respectively). At 3D-CE MRA, MIP images combined MPR, CPR and source images were superior to only using MIP images (P 〈 0.01 ,respectively), while 2D-TOF MRA, MIP images combined MPR, CPR and source images had not statistical difference to only using MIP images ( P 〉 0.01 ,respectively). Conclusion 3D-CE MRA is superior to 2D-TOF MRA for the evaluation of the intracranial sinus thrombosis, in which the combination of multiple postprocessing display modalities can provide better visualization of the extent of thrombosis, degree of occlusion and collateral veins drainage.
出处 《临床放射学杂志》 CSCD 北大核心 2006年第8期711-715,共5页 Journal of Clinical Radiology
关键词 窦血栓形成 磁共振血管成像 比较研究 Sinus thrombosis Magnetic resonance angiography Comparative study
  • 相关文献

参考文献14

  • 1Stolz E,Gerriets T,Bodeker RH,et al.Intracranial venous hemodynamics is a factor related to a favorable outcome in cerebral venous thrombosis.Stroke,2002,33:1645
  • 2Ayanzen RH,Bird CR,Keller PJ,et al.Cerebral MR venography:Normal anatomy and potential diagnostic pitfalls.Am J Neuroradiol,2000,21:74
  • 3高勇安,李坤成,王新民,杜冬泽.脑静脉窦血栓磁共振血流成像的诊断价值[J].中华放射学杂志,1997,31(12):805-808. 被引量:62
  • 4Scott JN,Farb RI.Imaging and anatomy of the normal intracranial venous system.Neuroimag Clin N Am,2003,13:1
  • 5于群,孔祥泉,刘定西,徐海波.磁共振静脉系血管成像对颅内静脉血栓的诊断价值[J].中国医学影像技术,2004,20(9):1343-1346. 被引量:11
  • 6查云飞,孔祥泉,刘定西,徐海波.三维对比增强磁共振血管成像对正常颅内静脉系统的显示[J].中国医学影像技术,2005,21(6):966-969. 被引量:13
  • 7Watanabe Y,Dohke M,Okumura A,et al.Dynamic subtraction contrast-enhanced MR angiography:technique,clinical applications,and pitfalls.Radiographics,2000,20:135
  • 8Liang L,Korogi Y,Sugahara T,et al.Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence:prospective comparison with 2D-TOF MR venography and digital subtraction angiography.Am J Neuroradiol,2001,22:481
  • 9L(o)vblad KO,Schneider J,Bassetti C,et al.Fast contrast-enhanced MR whole-brain venography.Neuroradiology,2002,44:681
  • 10Farb RI,Scott JN,Willinsky RA,et al.Intracranial venous system:gadolinium-enhanced three-dimensional MR venography with auto-triggered elliptic centric-ordered sequence-initial experience.Radiology,2003,226:203

二级参考文献25

  • 1于群,孔祥泉,刘定西,徐海波.磁共振静脉系血管成像对颅内静脉血栓的诊断价值[J].中国医学影像技术,2004,20(9):1343-1346. 被引量:11
  • 2高勇安,中华放射学杂志,1996年,30卷,198页
  • 3高勇安,临床放射学杂志,1994年,13卷,327页
  • 4Loubeyree P, De Jaehere T, Tran-Minh VA. Three-dimensional phase contrast MR cerebral venogaphy with zero filling interpolation in the slice encoding direction[J]. Magn Reson Imaging, 1999,117(8):1227-1233.
  • 5Essig M, Reichenbach JR, Schad LR, et al. High-resolution MR venography of cerebral arteriovenous malformations[J]. Magn Reson Imaging, 1999, 17(10):1417-1425.
  • 6Chakeres SW, Schmalbrock P, Brogan M, et al. Normal venous anatomy of the brain: demonstration with gadopentetate dimeglumine in enhanced 2D MR angiography[J]. AJR, 1989, 153(3): 755-760.
  • 7Ruehm SG, Zimny K, Debatin JF. Direct contrast-enhanced 3D MR venography[J]. Eur Radiol, 2001,11(1):102-112.
  • 8Ayanzen RH, Bird CR, Keller PJ, et al. Cerebral MR venography: normal anatomy and potential diagnostic pitfalls[J]. Neuroradiology, 2000,21(1): 74-78.
  • 9Ruehm SG. MR venography[J]. Eur Radio, 2003,13(2): 229-230.
  • 10Stevenson J, Knopp EA, Litt AW. MR-RAGE subtraction venography: a new technique[J]. Magn Reson Imaging, 1995, 5(2):239-241.

共引文献75

同被引文献117

引证文献10

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部