期刊文献+

ECR源的新工作模式 被引量:2

A New Working Mode for ECR Source
原文传递
导出
摘要 叙述了兰州重离子加速器ECR2源所使用的新工作模式的条件、特点及高电荷态离子束的输出性能,给出了对该模式特点的初步分析. In this paper a new working mode for ECR2 ion source of Heavy Ion Accelerator in Lanzhou is introduced The operating conditions, particular feature and the output of high charge state ions in this condihon are described. Some discussions on the new mode are also given.
出处 《高能物理与核物理》 CSCD 北大核心 1996年第10期957-960,共4页 High Energy Physics and Nuclear Physics
关键词 ECR 离子源 高电荷态离子束 重离子加速器 ECR ion source, high charge state ion beam, secondary electron emission,thermoelectron emission.
  • 相关文献

参考文献2

  • 1刘占稳,Proc of the 12th International Workshop on ECR Ion Source,1995年
  • 2Xie Zuqi,RSI,1991年,62卷,774页

同被引文献10

  • 1刘占稳 等.强激光与粒子束,1996,8(2):310-310.
  • 2Geller R, IEEE Trans Nucli Sci, 1976 NS-23(2) :904.
  • 3XIE Z Q, LYNEIS CM, "Performance of the Upgraded LBNL AECR Ion Source", Proc of the 13th Inter. Workshop on ECRIS, Texas A &M University, USA, 1997,16.
  • 4Liu Z W,ReviewScientificInstruments,1998年,69卷,2期,685页
  • 5Xie Z Q,ReviewScientificInstruments,1998年,69卷,2期,625页
  • 6Zhao H W,Proceedings of the 13th International Workshopon ECRI on Sources,1997年,34页
  • 7刘占稳,高能物理与核物理,1996年,20卷,4期,957页
  • 8Liu Z W,Proceedings of the 12th International Workshopon ECRI on Source,1995年,235页
  • 9Wei B W,Proceedings of the 13th International Conference on Cyclotrons and Their Applica,1993年,344页
  • 10袁平,刘占稳,张汶,赵红卫,张雪珍,郭晓虹,李锡霞,周嗣信,王义芳,魏宝文.金属筒在ECR2高电荷态离子源中的应用[J].原子能科学技术,1999,33(5):392-396. 被引量:2