期刊文献+

经胸二次谐波多普勒技术探测冠状动脉血流储备的研究

The analysis of coronary sinus flow reserve by transthoracic doppler echocardiography with second harmonic technique and evaluate the coronary sinus flow velocity reserve
暂未订购
导出
摘要 目的应用经胸二次谐波多普勒超声心动图(TTDE)检测冠状静脉窦血流储备(CSFR);与经食道多普勒超声心动图(TEE)探测左冠状动脉前降支血流速度计算血流储备(CFR)相对照,分析研究经胸探测冠状静脉窦血流储备(CSFR)可代替TEE的探测CFR可靠性。方法检测40例正常人,CSFR或CFR为潘生丁负荷试验后最大峰值血流速度与静息状态峰值血流速度的比值。利用TTDE探测CSFR,TEE探测CFR。结果TTDE探测CSFR的成功率为95%。TTDE所测的CSFR与TEE所测CFR值密切相关。结论TTDE为一种新的检测CFR的方法。 Objective To detect coronary sinus flow reserve by transthoracic Dopple echocardiography(TTDE)with second harmonic technique and evaluate the coronary sinus flow velocity reserve(CSFR)in comparison to transesophageal echocardiography(TEE)analysis,Methods CFR was assessed by TTDE and TEE in 40 patiends.CSFR/CFR was calculated as the ratio of hyperemiato baseline average pead velocity.CSFR was assessed by TIDE, CFR was assessed by TEE.Results In 38 (95%)of 40 patients ,CSFR was successfully determined with intravenous dipyridamole(DPM)infusion.CSFR determined from TTDE correlated closely with those from transesophageal echocardiogaphy (TEE) measurements(r=0.707,p〈0.0001).Conclusion TTDE is a new and noninvasion method,which can provide relable data on CFR.
出处 《宁夏医学杂志》 CAS 2006年第7期499-501,共3页 Ningxia Medical Journal
关键词 冠状静脉窦血流储备 二次谐波 经胸壁多普勒超声心动图 Conrnary sinus flow reserve Second harmonic technique transtharacic Doppler echocardiography(TTDE)
  • 相关文献

参考文献9

  • 1Caiati C,Montaldo C,Zedda N,et al.New noninvasive method for coronary flow reserve assessment.Contrast-enhanced transthoracic second harmonic echo Doppler[J].Circulation 1999,99:771-778.
  • 2Hozumi T,Yoshida K,Akasaka T,et al.Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography.Comparison with invasive thchnique[J].J Am Coll Cardiol,1998,32:1251-1259.
  • 3白晨,张薇,张运.经食管多普勒超声心动图测量冠状动脉血流储备研究方法进展[J].中国超声医学杂志,1997,13(5):65-67. 被引量:10
  • 4Thaker KB,Kawaanishi D,Narang YK,et al.Comparison of flow velocity in the left anterior descending coronary artery and coronary flow reserve,by intra coronary flow wire and transesophageal echocardiography[J].Circulation,1994,90:Ⅰ-276.
  • 5Yuen J,Strom JA,Monrad ES,et al.Validation of noninvasive determination of coronary vascular reserve by direct intra coronary measurement[J].Circulation,1993,88:Ⅰ-67.
  • 6Sam darshi NE,Nanda NC,Gatewood RP,et al.Usefulness and limitations of transesophageal echocardiography in the assessmemt of proximal coronary stenosis[J].J Am Coll Cardiol,1992,19:572-580.
  • 7杨娅,王新房,Thomas Bartel,Holger Eggebrecht,Loredana Latina,Raimund Erbel.新型无创性冠状动脉血流储备检测经胸壁声学造影二次谐波多普勒技术[J].中华心血管病杂志,2003,31(2):91-95. 被引量:11
  • 8Caiati C,Montaldo C,Zedda N,et al.Validation of a new noninvasive method (Contrast-enhanced transthoracic second harmonic echo Dopplor) for the evaluation of coronary flow reserve[J].J Am Coll Cardiol,1999,34:1193-1200.
  • 9何瑞荣.冠状动脉循环的生理.见:张鸿修,黄体钢主编.实用冠心病学[M].天津:天津科技翻译出版公司,2005.8-9.