布机挡车工个体噪声暴露样本含量与等效声级均数变异的关系 被引量:4

Relationship between sample size and variation of means for personal noise exposure in weaving workers
原文传递
导出
摘要 目的探讨个体暴露抽样例数与抽样数据均数变异的关系,为制订个体噪声暴露测量规范提供科学依据。方法以布机车间挡车工个体噪声暴露测量数据8 h等效连续A声级(LAeq·8h)为分析对象,采用可重复随机抽样方法从个体噪声暴露数据中抽取一定数量的样本,计算均数。每次抽样1-15个,抽样1000次时,分析抽样LAeq·8h均数变异的规律。结果抽样例数较少时,LAeq·8h均数的最大值、最小值、第95百分位数(P95)和第5百分位数(P5)曲线向均数靠拢的速度较快,抽样例数增大时变化趋于平缓。每次分别抽样1、4、7和11例时,LAeq·8h均数P95和P5的差值分别为7.40、3.30、2.44和1.85 dB,抽样4、7、11例时的LAeq·8h均数P95和P5差值分别约为抽样1例时的1/2、1/3和1/4。结论纺织厂布机挡车工每组的个体噪声暴露测量抽样例数在4-11例为宜。 Objective To explore the relationship between sample size and variance of means for personal noise exposure in weaving workers as to contributing evidence for establishing personal noise exposure measurement guideline. Methods A personal noise exposure measurement database from a group of weaving workers was used in the randomized re-sampling data analysis. The sampling cases were one number selecting from one to fifteen at each randomized re-sampling procedure. The randomized re-sampling was one thousand times from original personal noise exposure measurement database to get one thousands of re-sampling database. One thousands of LAeq·8h mean were calculated by re-sampling databases. The variation of randomized re-sampling means was analyzed for different re-sampling numbers. Results The change for narrow trend of maximum, minimum, 95 percent number, 5 percent number of LAoq. s h mean Was faster when randomized re-sampling number was smaller in variation vs randomized re-sampling number curve analysis. After that, the change for narrow trend of LAeq·8h mean was smooth for increasing the randomized re-sampling numbers. The 95% - 5% of LAeq·8h mean was about half for randomized re-sampling four cases (3. 30 dB) vs one case (7. 40 dB) , and about one third for seven cases (2. 44 dB), and about one fourth for eleven cases (1.85 dB ). Conclusion The sample size in personal noise exposure measurement guideline could be selected from four to eleven.
出处 《中华预防医学杂志》 CAS CSCD 北大核心 2006年第4期281-284,共4页 Chinese Journal of Preventive Medicine
基金 卫生部科学研究基金资助项目(98-1-270) 声场声信息国家重点实验室客座课题基金资助项目(1994-03-08)
关键词 抽样研究 噪声 职业性 Sampling studies Noise, occupational
  • 相关文献

参考文献7

二级参考文献17

  • 1丁茂平,许真,战庆长,穆玉梅,艾延廷,张润秋,金永哲.工业脉冲噪声对工人听觉的损害[J].中华劳动卫生职业病杂志,1993,11(6):334-337. 被引量:5
  • 2丁茂平,赵一鸣,穆玉梅,战庆长,金永哲,许真.脉冲与稳态噪声引起工人听力损伤的差异[J].中华劳动卫生职业病杂志,1995,13(2):72-74. 被引量:51
  • 3赵一鸣,张书珍.稳态噪声暴露与高血压剂量——反应关系的人群研究[J].职业卫生与应急救援,1995,13(1):11-13. 被引量:7
  • 4[2]Tomei F,Papaleo TP.Chronic noise exposure nad cardiovascular system in aircraft piaots.Med Lav,1996,87:394-410.
  • 5Alice H. Suter. The relationship of the exchange rate to noiseinduced heating loss. Noise/News International, 1993,1 : 131-151.
  • 6Hamrenik RP, Ahroon WA, Hsueh KD. The energy spectrum of an impulse: its relation to hearing loss. J Acoust Soc Am, 1991,90:197-204.
  • 7Hamemik RP, Qiu W. Energy-independent factors influencing noiseinduced heating loss in the chinchilla model. J Acoust Soc Am,2001, 110:3163-3168.
  • 8Hamernik RP, Qiu W, Davis B. The effects of the amplitude distribution of equal energy exposures on noise-induced heating loss :the kurtosis metric. J Acoust Soc Am, 2003, 114:386-395.
  • 9Lei SF, Ahreon WA, Hamernik RP. The application of frequency and time domain kurtosis to the assessment of hazardous noise exposures. J Acoust Soc Am, 1994, 96:1435-1444.
  • 10郑建如,万学文,赵一鸣,冉宴立,陈静.机械工业脉冲噪声对工人听力损害的研究[J].中国工业医学杂志,1997,10(1):19-20. 被引量:15

共引文献79

同被引文献45

引证文献4

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部