期刊文献+

中性束诊断电源系统及束流引出实验研究

Power system for diagnostic neutral beam and study on the experiment of neutral beam extraction
在线阅读 下载PDF
导出
摘要 HT-7中性束诊断电源系统的计算机控制系统由PLC、工控机、逻辑控制和定时单元等组成。对起弧、束流引出等实验进行了研究。在多种参数下,通过调节弧压、进气量等观察了其对弧流的影响。初步实验结果表明,在高压35kV、弧流80A的情况下,束电流可以达到3.6A,引出的中性束流功率可以稳定地达到50kW以上。 Control system of power supply for HT-7 diagnostic neutral beam source was composed of PLC, timer and master control logic. The experimental results show the good facility and reliability. The arcing and beam extraction are studied experimentally. The influences on the beam current are observed by adjusting arc voltage and gas injection at different cases. The neutral beam power of 50kW and beam current about 3.6A were obtained in this operation priod with 35kV HV and 80A arc current.
出处 《核聚变与等离子体物理》 EI CAS CSCD 北大核心 2006年第2期151-155,共5页 Nuclear Fusion and Plasma Physics
关键词 中性束诊断 电源系统 HT-7 Diagnostic Neutral Beam Power Supply System HT-7
  • 相关文献

参考文献2

  • 1David Terry, James W Jagger, David Pavlovsky, et al. Power system for the text diagnostic neutral beam source [A].Twelfth Symposium on Fusion Engineering, Monterey [C].California: the University of Texas, 1987. 452.
  • 2David A Pavlosky, ,lames W Jagger, David Terry, et al.Control system for the TEXT diagnostic neutral beam source [A]. Twelfth Symposium on Fusion Engineering,Monterey [C]. California: the University of Texas, October, 1987. 651.