期刊文献+

不同类型前路钢板固定应用于颈椎屈曲牵张型损伤的生物力学研究 被引量:1

Anterior plate fixation for cervical distractive flexion injuries:a biomechanical comparison of different types of design
原文传递
导出
摘要 目的探讨采用前路钢板固定颈椎屈曲牵张型损伤治疗的可靠性,并比较静力化固定和动力化固定等不同设计类型钢板在恢复损伤节段稳定性方面的差异。方法采用12具小牛颈椎标本,在C_(4,5)节段制作屈曲牵张损伤模型,切除椎间盘、植骨后随机分为3组,分别采用Orion、Codman、Window钢板、螺钉固定,测试手术固定各组在颈椎前屈、后伸、侧屈及旋转运动时的稳定性并与正常标本比较。结果颈椎屈曲损伤后,无论采用哪种钢板固定,其术后运动范围(ROM值)均比正常颈椎要大。Orion固定最接近正常标本,但在旋转运动时有明显差异。Codman固定仅在侧曲时的稳定性接近正常和Orion固定组。Window固定最弱,在各运动状态下的刚度均明显低于正常组。结论在颈椎屈曲牵张型损伤时,前路静力化固定相对稳定,动力化固定可能牺牲一定的固定强度,尤其是选择平移类设计的钢板固定更要谨慎。 Objective To evaluate the safety of dynamic anterior plate fixation for cervical distractive flexion injuries and compare its rigidity between different types of plate design. Methods Twelve sets of cadaveric calf spine were used in this test. All the specimens were made into distractive flexion injury models (C4-C5) according to Allen' s method. After discectomy and grafting, they were randomized into three groups in which Orion, Codman, and Window instrumentations were used respectively. The stiffness of each construct was tested in flexion, extension, lateral bending and axial torsion conditions sequentially. Results Compared with an intact cervical spine, the range of motion (ROM) of an injured cervical spine increased whatever plate was applied. Orion instrumentation presented stiffness the closest to that of the normal control, except for less torsional stiffness. Codman instrumentation provided stiffness close to that for normal and Orion groups only in lateral bending. Window's was the weakest and not enough in all kinds of movement. Conclusions Static anterior fixation is the first choice for cervical injuries. Dynamic plate fixation may sacrifice stiffness to some extent, especially when a shifting kind of design is to be chosen.
出处 《中华创伤骨科杂志》 CAS CSCD 2006年第6期553-556,共4页 Chinese Journal of Orthopaedic Trauma
关键词 颈椎 前路钢板 动力同定 生物力学 Cervical spine Anterior plate Dynamic instrumentation Biomeehanies
  • 相关文献

参考文献14

  • 1Epstein NE. Anterior dynamic plates in complex cervical reconstructive surgeries. J Spinal Disord Tech, 2002, 15:221-227.
  • 2Hiad RW, Foley KT, Rodts GE, et al. The cervical spine study group anterior plate nomenclature. Neruorosuge Focus, 2002,12 : 15.
  • 3Reidy D, Finkelstein J, Nagpurkar A, et al. Cervical spine loading characteristics in a cadaveric C5 corpectomy model using a static and dynamic plate. J Spinal Disord Tech, 2004,17: 117-122.
  • 4Brodke DS, Gollogly S, Mohr RA, et al. Dynamic cervical plates. Biomechanical evaluation of load sharing and stiffness.Spine, 2001, 26: 1324-1329.
  • 5Allen BL Jr, Ferguson RL, Lehmann TR, et al. A mechanistic classification of closed indirect fractures and dislocations of the lower cervical spine. Spine, 1982, 7: 1-27.
  • 6Panjabi MM. Biomechanical evaluation of spinal fixation devices: I. A conceptual framework. Spine, 1988, 13:1129-1134.
  • 7Varccaro AR, BalderstonRA. Anterior plate instrumentation for disorders of the subaxial cervical spine. Clin Orthop, 1997,(335): 112-121.
  • 8孙宇,王超,党耕町,王少波,齐强,王志国.颈椎侧块钢板螺钉内固定术治疗下颈椎骨折脱位[J].中华骨科杂志,2000,20(3):150-153. 被引量:54
  • 9Aebi M, Zuber K, Marchesi D. Treatment of cervical spine injuries with anterior plating. Indications, techniques, and resuits. Spine, 1991, 16 (3 Suppl): 38-45.
  • 10Razack N, Green BA, Levi AD. The management of traumatic cervical bilateral facet fracture-dislocations with unicortical anterior plates. J Spinal Disord, 2000, 13: 374-381.

二级参考文献4

共引文献58

同被引文献16

  • 1孙钢,金鹏,易玉海,谢宗贵,谢志勇,张绪平,张殿星.经皮椎体成形术治疗颈椎转移瘤的初步研究[J].中华放射学杂志,2004,38(6):601-604. 被引量:25
  • 2郑召民.经皮椎体成形术和经皮椎体后凸成形术灾难性并发症——骨水泥渗漏及其预防[J].中华医学杂志,2006,86(43):3027-3030. 被引量:142
  • 3郭卫,汤小东,李大森,杨毅,董森.脊柱转移瘤的外科治疗效果[J].中国脊柱脊髓杂志,2006,16(12):905-908. 被引量:9
  • 4Tokuhashi Y,Ajiro Y,Oshima M.Algorithms and planning in metastatic spine tumors.Orthop Clin North Am,2009,40:37-46.
  • 5Ratliff JK,Cooper PR.Metastatic spine tumors.Southern Med J,2004,97:246-253.
  • 6Tomita K,Kawahara N,Kobayashi T,et al.Surgical strategy for spinal metastases.Spine,2001,26:298-306.
  • 7Harrington KD.The use of methylmethacrylate for vertebral-body replacement and anterior stabilization of pathological fracturedislocations of the spine due to metastatic malignant disease.J Bone joint Surg Am,1981,63:36-46.
  • 8Robert AH,Stefano B,Roberto B,et al.A system for surgical staging and management of spine tumors:a clinical outcome study of giant cell tumors of the spine.Spine,1997,22:1773-1782.
  • 9Tokuhashi Y,matsuzaki H,Oda H,et al.A revised scoring system for preoperative evaluation of metastatic spine tumor prognosis.Spine,2005,30:2186-2191.
  • 10Abumi K,Kaneda K,Shono Y,et al.One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screw fixation systems.J Neurosurg,1999,901 Suppl:19-26.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部