期刊文献+

Smart Prep技术在肾动脉CTA中的临床应用 被引量:4

The clinical application of the Smart Prep technique in renal artery CTA
暂未订购
导出
摘要 目的:探讨Smart Prep技术在肾动脉多层螺旋CT血管造影中的应用.方法:20例行同层动态增强扫描,通过时间-密度曲线获得肾动脉的有效浓度阈值.65例行肾动脉CTA造影,经肘静脉团注370mgI/ml优维显1.5ml/kg后,应用Smart Prep软件实时监控靶血管浓度,当感兴趣区对比剂浓度达有效浓度阈值时触发增强扫描完成数据采集,重组和重建图像显示肾动脉.结果:65例肾动脉CTA造影均获成功,58例(89.2%)增强时相处于最佳扫描时期.增强扫描的延迟时间15~38s不等,个体差异明显,而肾动脉CT值持续位于有效浓度阈值 (100HU)以上.结论:Smart Prep技术实时监控肾动脉对比剂浓度变化并及时触发增强扫描,它不受个体差异影响即可确保增强扫描的实施,优于小剂量试验. Objective: To explore application of the Smart Prep technique in MSCTA of renal artery. Methods: The timing boluses were performed in twenty eases and the parameters such as effective concentration threshold of renal artery were obtained by the time-density curve. Sixty-five cases of renal artery CTA were performed and Smart Prep software was used to monitor the concentration of target vessel in real time after 1.5ml/kg of contrast medium quickly injected into elbow vein. While the concentration of contrast in regions of interst reached the threshold, the scanning was triggered to start collecting data, and three dimensional reconstruction of CTA was performed. Results:All 65 cases of renal artery CTA succeeded. Fifty-eight of sixty-five cases(89.2%) were in an optimal enhancement scanning phase. The triggering time of enhancement scanning were from 15 to 38 seconds due to individual difference and the concentration of target vessel hold above 100 HU in all cases lastly. Conclusion:The Smart Prep technique monitores concentration fluctuation of contrast in real time and could trigger the scan in time. It is immune to individual difference and can exactly carry out enhancemem scanning and it is better than the small-dose tests.
出处 《医学影像学杂志》 2006年第5期483-485,共3页 Journal of Medical Imaging
关键词 肾动脉 体层摄影术 X线计算机 监控触发技术 Renal artery Tomography, X-ray computed Monitored-triggered technique
  • 相关文献

参考文献6

二级参考文献13

  • 1[4]Tanaka J, Tsukuda S, Amanuma M, et al. Detection of recurrent rectal cancer using helical CT with SmartPrep: a new technique for obtaining optimal contrast enhancement[J]. Nippon Igaku Hoshasen Gakkai Zasshi,1998,58(4):160-162.
  • 2Pannu HK, Fishman EK. Multidetector computed tomographic evaluation of the renal artery[J].Abdom imaging,2002,27(6) : 611 -619.
  • 3Mallouhi A, Rieger M, Czeamak B,et al. Volume-rendered multidetector CT angiography:noninvasive follow-up of patients treated with renal artery stents[J]. AJR, 2003,180( 1 ) :233 - 239.
  • 4Behar JV, Nelson RC, Zidar JP, et al. Thin-section multidetector CT angiography of renal artery stenta[J]. AJR, 2002, 178(5): 1155 -1159.
  • 5Urban BA, Rather LE, Fishman Ek. Three-dimesional volume-rendered CT angiography of the renal arteries and veins: normal anatomy,variants and clinical applications[J]. Radiographics, 2001,21 (2) : 373- 386.
  • 6Li C F,中华放射学杂志,1999年,33卷,7期,483页
  • 7Zhou C S,中华放射学杂志,1998年,32卷,2期,127页
  • 8Oliver J H,Radiology,1996年,201卷,1期,1页
  • 9Van Leeuwen M S,Radiology,1996年,201卷,2期,327页
  • 10Tomiak M M,AJR,1995年,164卷,6期,1525页

共引文献100

同被引文献30

  • 1马焱鑫,高丽媛,杨月娥,刘影,毕纯龙.多层螺旋CT作肾动脉造影在高血压筛查中的临床应用价值[J].CT理论与应用研究(中英文),2005,14(2):50-53. 被引量:3
  • 2涂备武,周康荣.小肝癌CT增强动脉期时间密度曲线特征及其病理分析[J].实用放射学杂志,2005,21(9):926-928. 被引量:16
  • 3吕发金,罗天友,谢鹏,张志伟,沈云,牟君,廖静敏,方维东,陈垦.数字减影CTA图像质量影响因素探讨[J].重庆医科大学学报,2007,32(3):271-274. 被引量:60
  • 4高红,徐文坚,李绍科,郝大鹏.64层螺旋CT主动脉成像技术的临床应用[J].中国医学影像技术,2007,23(1):77-80. 被引量:6
  • 5Kim S K,Lim J H,Lee W J,et al.Delection of hepatic carcinoma:Comparison of dynamic threephase computed tomography images and fourphase computed tomography images using multidetector row helical tomography[J].J Comput Asist Tomogr,2002,26(5):691-698.
  • 6Femaner M P,Redvanly R D.Primary hepatic malignant neoplasm[J].Radiol Clin North Am,1998,36(2):333-348.
  • 7李果珍.临床CT诊断学[M].上海:上海医科大学出版社,2000:54-55.
  • 8Tanoue S, Kiyosue H, Kenai H, et al. Three-dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: surgical correlation [J]. Neurosurgery, 2000,47(4) :866-871.
  • 9Sahani DV, Kalva SP, Hahn PF, et al. 16-MDCT angiography in living kidney donors at various tube potentials: impact on image quality and radiation Dose. AJR Am J Roentgenol, 2007,188(1) : 115-120.
  • 10Michaely H J, Herrmann KA, Kramer H, et al. High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors. J Magn Reson Imaging, 2006,24(1) :95-100.

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部