期刊文献+

一种新的聚合物颗粒用于奥硝唑测定的研究

Determination of Ornidazole Using a Kind of Novel Polymer Particles
在线阅读 下载PDF
导出
摘要 利用水包油乳液聚合法制备包裹了萘硼酸(NBA)的聚合物颗粒。此聚合物颗粒可用于奥硝唑的测定,其耐光漂白性,抗干扰性与游离萘硼酸相比,均有一定程度的提高。当聚合物颗粒的浓度固定为0.2mg/mL时,其对奥硝唑的线性响应范围为0.8~80/μmol/L,检测下限为0.5μmol/L。 A kind of polymer particles encapsulated naphthaleneboronic acid (NBA) was prepared via an oilin-water emulsion polymerization process. The resulting polymer particles were used to determine ornidazole, their capacities to resist photobleaching and interferences were improved as compared to those of free naphthaleneboronic acid. When the concentration of the polymer particles was fixed at 0. 2 mg/mL, it showed a linear response toward ornidazole in the range of 0.8μmol/L to 80/μmol/L with a detection limit of 0.5μmol/L.
出处 《传感技术学报》 EI CAS CSCD 北大核心 2006年第3期545-548,共4页 Chinese Journal of Sensors and Actuators
基金 国家自然科学基金资助项目(20205005)
关键词 乳液聚合 聚合物颗粒 萘硼酸 奥硝唑 emulsion polymerization polymer particles 1-naphthaleneboronic acid ornidazole
  • 相关文献

参考文献10

  • 1Wang M H, Tan ZC, Sun X H, et al. Heat Capacity and Thermodynamic Properties of Crystalline Ornidazole (C7 H10 ClN3O3) [J]. Thermochim. Acta, 2004, 414(1):25-30.
  • 2WS1-(X-454)-2003Z,中华人民共和国卫生部药物标准[S].北京:中国标准出版社,2003.
  • 3Ozkan S A, Senturk Z, Biryol I. Determination of Ornidazole in Pharmaceutical Dosage Forms Based on Reduction at an Activated Glassy Carbon Electrode[J]. Int J Pharm, 1997, 157(3):137-144.
  • 4李芹,陈建中,郭瑞臣.奥硝唑血药浓度的高效液相色谱法测定及其国产和进口片剂的药动学和生物等效性研究(英文)[J].中国现代应用药学,2004,21(2):129-132. 被引量:6
  • 5梁小庆,石涛.奥硝唑注射液的HPLC测定[J].中国医药工业杂志,2002,33(2):93-94. 被引量:18
  • 6Tan S Z, Jiang J H, Shen G L, et al.A Novel Fluorescence Probe for Cilnidipine Assay [J]. Analytica Chimica Acta,2005, 547(2):215-220.
  • 7Kurihara K, Ohtsu M, Yoshida T, et al. Micrometer-Sized Sodium Ion-Selective Optodes Based on a “Tailed” Neutral Ionophore[J]. Anal. Chem, 1999, 71(16): 3558-3566.
  • 8Suzuki K, Ohzora H, Tohda K, et al. Fiber-Optic Magnesium and Calcium Ion Sensor Based on a Natural Carboxylic Polyether Antibiotic[J]. Anal Chem, 1989,61(4):382-384.
  • 9Seiler K, Simon W. Hydration of Trifluoroacetophenones as the Basis for an Optical Humidity Sensor [J]. Anal Chim Acta, 1992, 266(1): 73-77.
  • 10Hisamoto H, Watanabe K, Nakagawa E, et al. Flowthrough Type Calcium Ion Selective Optodes Based on Novel Neutral Ionophores and a Lipophilic Anionic Dye [J]. Anal.Chim. Acta, 1994, 299(2): 179-187.

二级参考文献6

  • 1许明旺,陈斌,余文光.高效液相色谱法测定替硝唑片的含量[J].中国医院药学杂志,1996,16(10):455-456. 被引量:9
  • 2Merdjan H, Bonnat C, Singlas E, et al. Measurement of ornidazole by high performance liquid chromatography[J]. Chromatography, 1983, 273:475.
  • 3Heizmann P, Geschke R, Zinapold K. Determination of ornidazole and its main metabolites in biological fluids[J]. Chromatography, 1990,534:233.
  • 4Martin C, Bruguerolle B, Mallet N, et al. Pharmacokinetics and tissue penetration of a single dose of ornidazole for antibiotic prophylaxis in colorectal surgery[J]. Antimicrob Agents Chemother, 1990, 34:1921.
  • 5Turcant A, Granry JC, Allain P, et al. Pharmacokinetics of ornidazole in neonates and infants after a single intravenous infusion[J]. Eur J Clin Pharmcol 1987,32:111.
  • 6方子季,孙蕙卿,王月军,隋志愿.HPLC法测定甲硝唑泡腾片[J].药物分析杂志,1998,18(5):335-336. 被引量:9

共引文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部