期刊文献+

超声刀腹腔镜胆囊切除术 被引量:20

Lapascopic cholecystectomy by using harmonic scalpel
暂未订购
导出
摘要 目的探讨超声刀在腹腔镜胆囊切除术中的应用。方法A组为该院1997 ̄2003年间收治的腹腔镜超声刀胆囊切除术患者78例,B组为随机抽取同期应用高频单极电刀实施腹腔镜胆囊切除术患者200例,两组进行比较。结果两组病例在住院时间、术后胆漏、高烧、出血、中转开腹等情况上差异无显著性。A组病例平均手术时间长于B组。结论应用超声刀进行腹腔镜胆囊切除术是可行的,可避免传统高频电刀造成的电流及金属残留等潜在危险从而更加安全。 [Objective] To evaluate the usage of harmonic scalpel in cholecystectomy prosedures. [Methods] In group A, 78 cases of the laparascopic chelocystectomy (LC) by using harmonic scalpd from 1997 to 2003. In group B, 200 cases of the traditional laparascopic chelocystectomy (LC) were randomly seleted. These two groups were compared in statistic method. [Result] The average hospital stay, the morbidity of bile leakage, high fever, bleeding and conversion rate between these two groups are similar. The average operation time in group A was longer than in group B. [Conclusion] Ultrasound dissection technology was feasible, at the same time avoid the potential risks of current injury, metal material left in the abdomen etc. and then more safety.
出处 《中国内镜杂志》 CSCD 北大核心 2006年第5期462-463,466,共3页 China Journal of Endoscopy
关键词 超声刀 高频单极电刀 腹腔镜胆囊切除术 胆囊疾病 ultrasonic harmonnic scalpel high-frequency electronic mono-polar scalpel laparascopic chelocystectomy
  • 相关文献

参考文献7

  • 1LIU GL. Current status of Laparoscopie Surgery in China: Review of more than 150,000 cases[J]. Dig Endosc, 1999, 11(3):215-219.
  • 2TUCKER RD. Laparoscopic electrosurgical injuries: survey results and their implications [J]. Surg Laparesc Endosc, 1995, 5 (2):311-317.
  • 3KANEHIRA E, OMURA K, KINOSHITA T, et al. How secure are the arteries occluded by a newly developed ultrasonically activated device[J]. Surf Endoc, 1999, 13(4): 340-342.
  • 4ALLAN E, AIPERSTEIN, BERBER E, et al. The use of harmonic scalpel vs convensional knot tying for vessel ligation in thyroid surgery[J]. Arch Surg, 2002, 13(3): 137-142.
  • 5王明亮,臧潞,郑民华,蒋渝,李烨.超声刀对胆囊管钳闭作用的实验研究[J].中国内镜杂志,2005,11(5):449-450. 被引量:6
  • 6谭洪波,唐小钢.腹腔镜胆囊切除术并发症的原因及预防[J].中国内镜杂志,2004,10(4):110-110. 被引量:7
  • 7张雪峰,金红旭,李瑾,吴国强,宗修锟.LigaSure在腹腔镜下巨脾切除中的应用[J].中国内镜杂志,2005,11(5):499-500. 被引量:13

二级参考文献16

  • 1张雪峰,金红旭,李瑾,吴国强,蒋会勇,宗修锟,郑成竹.手助腹腔镜下脾切除门奇断流术(附12例报告)[J].消化外科,2004,3(4):247-249. 被引量:30
  • 2冯缵冲.输卵管阻塞的非手术治疗[J].实用妇产科杂志,1996,12(6):288-290. 被引量:27
  • 3DEO SVS, SHUKLA NK, ASTHANA S, et al. A comparative study of modified radical mastectomy using harmonic scalpel and electrocautery[J]. Singapore Med J, 2002, 43(5): 226-228.
  • 4TAKAO S, SHINCHI H, MUEMURA K, et al. Ultrasonically activated Scalpel is an effective tool for cutting the pancreas in biliary-pancreatic surgery: experimental and clinical studies[J]. J Hepatobiliary Pancreat Surg, 2000, 7(1): 58-62.
  • 5POWER C, MAGUIRE D, MCANENA OJ, et al. Use of the ultrasonic dissecting scalpel in laparoscopic cholecystectomy[J]. Surg Endosc, 2000, 14(11): 1070-3Allan E.
  • 6ALLAN E, SIPERSTEIN, BERBER E, et al. The use of harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery[J]. Arch Surg, 2002, 137: 137-142.
  • 7DAVID R, HOLT, DAVID VAN THIEL, et al. Hepatic Resections[J]. Arch Surg 2000, 135: 1353-1358.
  • 8MATTEWS BD, PRATT BL, BACKUS CL, et al. Effectiveness of the ultra-sonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery:a comparative analysis[J]. Am Surg, 2001, 67(9): 901-906.
  • 9ROMANO F, CAPROTTI R, FRANCIOSI C, et al. Laparoscopic splenectomy using Ligasure. Preliminary experience[J]. Surg Endosc, 2002, 16(11): 1608-1611.
  • 10乐杰.全国高等医药院校教材妇产科学[M](第5版)[M].北京:人民卫生出版社,2002.463.