摘要 提出了一种用于标定红外热像仪的黑体辐射源,黑体腔形状为球形,开孔直径与球腔直径之比为0.13。由恒温液体浴保证黑体腔温度分布均匀,采用水浴和酒精浴时,壁耐最大温差低于0.2℃,油浴时壁面最大温差低于0.3℃。该黑体辐射源升温快,控温稳定性好,工作温度范围可达-20~300℃,有效比辐射率大于0.998。 A kind of blackbody radiation source for calibration of infrared thermal imager is presented. The geometry of radiation cavity is sphere and the ratio of aperture/sphere diameter is 0. 13, In water and alcohol bath the maximum deviation of wall temperature of cavity is less than 0.2℃ and in silicon oil it is less than 0.3℃. The response time of the blackbody is short and the stability of controlling temperature is good. Temperature range of it is from -20℃ to 300℃ and its effective emissivity is above 0. 998.
出处 《仪器仪表学报》 EI CAS CSCD 北大核心 2006年第5期533-535,共3页 Chinese Journal of Scientific Instrument
关键词 黑体 校准 红外热像仪 温度测量 Blackbody Calibration Infrared thermal imager Temperature measurement
  • 相关文献

参考文献5

  • 1孙志君.红外焦平面阵列热摄像仪市场[J].今日电子,2003(2):43-45. 被引量:1
  • 2XIE Z, GAO K M, SHAN G H. Development of the infrared blackbody source of gravity-type heatpipe and study of its characteristics. Proceedings of SHE, (1311):415-419.
  • 3章熙民,诸凯,李惟毅,张沁芳,张伯礼,张金英,刘华一.应用红外热象技术测试舌面温度的研究[J].天津大学学报,1991,24(3):20-24. 被引量:12
  • 4JURGEN HARTMANN, JOACHIM FISCHER.Calibration and investigation of infrared camera systems applying blackbody radiation. Proceedings of SPIE, 2001(4360): 402-411.
  • 5ULRICH MESTER, PETER WINTER. New black-body calibration source for low temperatures from-20 to + 350 C. Proceedings of SHE, 2001(4360):372-380.

二级参考文献1

  • 1团体著者,1985年

共引文献11

同被引文献58

引证文献11

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部