期刊文献+

预富集-冷原子吸收光谱法测定水中的痕量汞 被引量:2

Cold atomic absorption spectrometry determination of trace mercury in water after pre-enrichment
在线阅读 下载PDF
导出
摘要 建立了一种预富集-冷原子吸收光谱法测定水中的痕量汞的方法,研究了预富集条件、测定条件等对灵敏度的影响。在最佳的条件下,用这个方法测定水样中的痕量汞,150ml样品中,特征质量为0.01ng/1%,标准偏差为0.0008- 0.001.回收率为95.0%-100.0%,结果较为满意。 A method of determining trace mercury in water by the cold atomic absorption spectrometry after pre-enrichment was established. The influence of pre-enrichment and determination conditions on sensitivity was studied. Under the optimum operation conditions of determining trace mercury in 150 ml water sample, the quality was 0.01 ng/l%, the standard deviation (SD) ranged from 0.0008 to 0.001, and the recovery was 95.0% - 100.0%. The results were relatively satisfactory.
机构地区 中南林学院
出处 《饮料工业》 2006年第4期41-42,共2页 Beverage Industry
关键词 预富集 冷原子吸收光谱法 mercury water pre-enrichment cold atomic absorption spectrometry
  • 相关文献

参考文献4

  • 1SUSAN D RICHARDSON.Water analysis[J].Analysis Chemistry,1999(71):181~215.
  • 2KATSUNORI ANEZAKI,XUEZECHEN,TAMOTSUOGASAWARA,ISOSHI NKATSUKA,KUNNIO OHZEKI.Determination of Cadmium and Lead in tap water by graphite-furnace atomic absorption spectrometry after ion-exchange resins the pyrrolidinedithiocarbamate complexes[J].Analytical Sciences,1998(14):523~527.
  • 3KATSUNORI ANEZAKI,ISOSHI NUKATRUKA,KUNNIO OHZEKI.Determination of Arsenic (Ⅲ) and total Arsenic (Ⅲ,Ⅴ) in water samples by resin suspension graphite furnace atomic absorption spectrometry[J].Analytical Sciences,1999(15):829~834.
  • 4HASAN CESUR.Determination of Manganese,Copper,Cadmium and Lead by FAAS after solid-phase extraction of their phenylpiperazine dithiocarbamate complexes on activated carbon[J].Turk Journal of Chemistry,2003(23):307~314.

同被引文献40

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部