期刊文献+

四柱式一体化拉压加载和转动装置的研制 被引量:2

Development of a four-post frame integral loading/rotating device
在线阅读 下载PDF
导出
摘要 介绍了自行研制的用于材料拉压加载试验实时同步辐射CT分析系统的一体化拉压加载和转动装置.该装置通过上下夹头的同步转动实现了试件相对于机架的刚性转动,通过上夹头相对机架的轴向运动实现了对试件的拉压加载.装置采用五隔板四柱式刚性机架,且五隔板的中心通孔形成了机架的中心基准;装置还采用了过定位设计、直线滚动轴承、高精度滚珠丝杠副、高定心夹头以及高精度同步闭环控制等技术,实现了试件高精度的几何运动和定位.对装置的精度检测表明,其实际精度优于设计指标.用以该装置为核心设备所组建的材料拉压加载试验实时同步辐射CT分析系统对泡沫铝进行的压缩和CT实时分析试验初步表明,该装置是可靠的. An integral loading/rotating device for real-time synchrotron radiation CT system for materials analysis is introduced. With this device, rigid rotation of the specimen was realized by synchronous rotation of the upper and low grips, and the specimen was loaded (tension/compression) by the axial movement of the upper grip. The device adopted a five-dummy-plate four-post framework and the five dummy plates' center through holes formed the center datum of the framework; moreover, the device adopted many other techniques, such as excessive position fix, straight-line rolling bearing, high delicate ball screw, high centring grip holder and high-precision synchronously closed-loop control and so on. All the techniques mentioned above assured the high accuracy in geometry motion and positioning of the device. Measurement of the device indicates that the actual accuracy is better than that of the original design. The compression test and real-time CT analysis on the foam aluminium with the real-time synchrotron radiation CT system for material analysis constructed based on this device was conducted, which proved the reliability of the device.
出处 《中国科学技术大学学报》 CAS CSCD 北大核心 2006年第4期402-407,共6页 JUSTC
基金 国家自然科学资金(10232030) 中国科学院高能物理研究所同步室BSRF基金资助
关键词 同步辐射CT 一体化装置 过定位 直线滚动轴承 闭环控制 synchrotron radiation CT integral device excessive position fix straight-line rolling bearing closed-loop control
  • 相关文献

参考文献9

  • 1庄天戈.CT原理和算法[M].上海交通大学出版社,1992..
  • 2Kinney J H,Johson Q C,Saroyan R A,et al.Energymodulated X-ray microtomography[J].Rev.Sci.Instrument,1988,59(1):196-197.
  • 3Ulrich Bonse,Frank Busch.X-ray computed microtomography(CT) using synchrotron radiation (SR)[J].Prog.Biophys.Molec.Biol.,1996,65 (1/2):133-169.
  • 4Bossi R H,Georgeson G E.Composite structure development decisions using X-ray CT measurements[J].Mater.Evalu.,1995:1198-1203.
  • 5Olurin O B,Arnold M,Korner C,et al.The investigation of morphometric parameters of aluminium foams using micro-computed tomography[J].Materials Science and Engineering,2002,A325:334-343.
  • 6Elmoutaouakkil A,Fuchs G,Bergounhon P,et al.Three-dimensional quantitative analysis of polymer foams from synchrotron radiation X-ray microtomography[J].J Phys.D:Appl.Phys,2003,36:A37-A43.
  • 7Kinney J H,Stock S R,Nichols M C,et al.Nondestructive investigation of damage in composites using X-ray tomographic microscopy (XTM)[J].J Mater.Res.,1990,5(5):1123-1129.
  • 8Hirano T,Usami.In situ X-ray CT under tensile loading using synchrotron radiation[J].J Mater.Res.,1995,10(2):381-32.
  • 9李大应,胡小方,夏源明.材料拉压加载试验实时同步辐射CT分析系统[J].实验力学,2006,21(3):292-298. 被引量:6

二级参考文献10

  • 1Suzuki Y,Usami K,Sakamoto K,et al.X-ray computerized tomography using monochromated synchrotron radiation[J].Japanese Journal of Applied Physics,1988,27(3):L461~L464.
  • 2Hiranio T,Usami K.High resolution monochromatic X-ray tomography using synchrotron radiation[J].Japanese Journal of Applied Physics,1989,28(2):263~266.
  • 3Bonse Ulrich,Busch Frank.X-ray computed microtomography(μCT) using synchrotron radiation(SR)[J].Prog.Biophys.Molec.Biol,1996,65(1/2):133~169.
  • 4Kinney JohnH,Johson Quintin C,Saroyan R Allyn.Energy-modulated X-ray microtography[J].Rev.Sci.Instrument,1988,59(1):196~197.
  • 5Kinney J H,Stock S R,Nichols M C,et al.Nondestructive investigation of damage in composites using X-ray tomographic microscopy(XTM)[J].J.Mater.Res,1990,5(5):1123~1129.
  • 6Buffiere J-Y,Maire E,Verdu C,et al..Damage assessment in an Al/SiC composte during monotonic tensile tests using synchrotron X-ray microtomography[J].Materials Science and Engineering,1997,A234-236:633~635.
  • 7Olurin O B,Arnold M,Korner C,et al..The Investigation of morphometric parameters of aluminium foams using micro-computed tomography[J].Materials Science and Engineering,2002,A328:334~343.
  • 8Youssef S,Maire E,Gaertner R.Finite element modeling of the actual structure of cellular materials determined by X-ray tomography[J].Acta Materialia,2005,53:719~730.
  • 9Hirano T,Usami K.In situ X-ray CT under tensile loading using synchrotron radiation[J].J.Mater.Res,1995,10(2):381~386.
  • 10庄天戈.CT原理和算法[M].上海:上海交通大学出版社,1992

共引文献6

同被引文献23

引证文献2

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部