摘要 目的评价国产封堵器治疗并发重度肺动脉高压动脉导管未闭(PDA)的可行性及近期效果。方法采用经导管国产封堵器堵闭并发重度肺动脉高压PDA 9例,术后进行经胸超声心动图、X线及心电图复查随访。结果9例均封堵成功;2例术后残余分流,在30 d随访中完全消失;血流动力学及心功能在术后和随访期间均有显著改善。全部病例均无严重并发症。结论应用国产封堵器治疗并发重度肺动脉高压PDA,安全可行,近期效果好。 AIM To evaluate the feasibility and effectiveness of transcatheter closure of patent ductus arterious (PDA) complicated severe pulmonary hypertension (SPH) with China-made occluders. METHODS Nine patients with PDA complicated SPH were occluded with China-made occluders and followed up for 1 to 2 days and 30 days after treatment. RESULTS All the 9 patients were occluded successfully. There was small residual shunt in two patients, which vanished slowly during the 30 day follow-up. The pulmonary artery pressure (PAP) was gravitated 22 -60 mmHg. The capacity of left ventricular improved obviously. There were no severe complications. CONCLUSION Transcatheter closure of PDA with severe pulmonary hypertension with China-made occluders is not only safe and feasible but has very good short-term result.
出处 《心脏杂志》 CAS 2006年第2期208-210,共3页 Chinese Heart Journal
基金 国家十五攻关项目资助(No.2001BA706B09)
关键词 动脉导管未闭 放射学 介入性 国产封堵器 重度肺动脉高压 patent ductus arterious radiology, interventional occluders made in home severe plumonic pressure
  • 相关文献

参考文献7

  • 1Masura J,Walsh KP,Thanopoulous B,etal.Catheter closure of Moderate to large sized patent ductus arteriosus using the newAmplatzer duct occluder:Immediate and short-term results[J].J Am Coll Cardiol,1998,31(4):878-882.
  • 2石继军,曾国洪,张智伟,王慧深,钱明阳,李渝芬.国产动脉导管未闭封堵器的临床应用及疗效评价[J].中华放射学杂志,2003,37(8):723-726. 被引量:29
  • 3秦永文,赵仙先,吴弘,郑兴,丁继军,胡建强.成角动脉导管未闭封堵器的临床应用[J].介入放射学杂志,2004,13(2):114-116. 被引量:22
  • 4Krichenko A,Benson LN,Burrows P,et al.Angiographic classification of the isolatedpersistently patent ductus arteriosus and implication for percutaneous catheterocclusion[J].Am J Cardiol,1989,63:877.
  • 5蒋世良,戴汝平,赵世华,张戈军,黄连军,曾筝,凌坚,金敬琳,谢若兰,郑宏,张岩.应用Amplatzer封堵器治疗动脉导管未闭[J].中华放射学杂志,1999,33(11):745-748. 被引量:76
  • 6Pietra GG,Capron F,Stewart S,et al.Pathologic assessment of vasculopathies in pulmonaryhypertension[J].J Am Coll Cardiol,2004,43(12 Suppl S):25S-32S.
  • 7Amin Z,Gu XP,Berry JM,et al.New device for closure of muscular ventricular septaldefects in a canine model[J].Circulation,1999,100(3):320 -328.