期刊文献+

根尖切除术中不同器械对于根尖倒预备的影响 被引量:7

Comparison between slow-speed handpiece and ultrasonic instrument in retropreparation of root-end in apicectomy
暂未订购
导出
摘要 目的比较根尖切除术中传统慢速手机与超声器械对于根尖倒预备的不同影响。方法借助扫描电镜对48颗离体前磨牙进行观察研究,使用AutoCAD2005制图软件辅助计算。结果使用传统慢速手机进行根尖倒预备后的牙根硬组织最小厚度(均值0.15mm)明显低于使用超声器械(S129D均值0.82mm,S129均值0.76mm),具有统计学显著意义(P<0.05)。结论使用超声器械进行根尖倒预备可以有效的保护牙根硬组织,保持牙根的强度。 Objective :To evaluate the effect of retrograde preparation by using slow-speed handpiece or by ultrasonic tips. Methods:Forty-eight extracted premolars were inspected with Scanning Electron Microscope for the minimum dentine thickness recorded after preparation of root-end cavities by low-speed handpiece and ultrasonic instrument respectively. Results: By using slow-speed handpiece, the minimum dentine thickness recorded after the preparation of root-end cavities was 0.15 mm;whereas that was 0.82 mm and 0.76 mm by ultrasonic instrument with S12 9D and S12 9 respectively( handpiece vs uhrosonic instrument, P 〈 0.05 ). Conclusion: Ultrasonic instrument is feasible in the retropreparation of root-end in apicection.
出处 《实用口腔医学杂志》 CAS CSCD 北大核心 2006年第2期159-161,共3页 Journal of Practical Stomatology
关键词 扫描电镜 超声器械 根尖倒预备 Scanning electron microscopic Ultrasonic instruments Retropreparation
  • 相关文献

参考文献12

  • 1Mehlhaff DS,Marshall JG,Baumgartner JC.Comparison of ultrasonic and high-speed-bur root-end preparations using bilaterally matched teeth.J Endod,1997,23(7):448.
  • 2Wuchenich G,Meadows D,Torabinejad M.A comparison between two root end preparation techniques in human cadavers.J Endod,1994,20(6):279.
  • 3Saunders WP,Saunders EM,Gutmann JL.Ultrasonic root-end prepration.Part 2:Microleakage of EBA root-end fillings.Int Endod J,1994,27(6):325,
  • 4Lloyd A,Gutmann J,Dummer P,et al.Microleakage of Diak and amalgam in root-end cavities prepared using MicroMega sonic retro-protips.Int Endon J,1997,30:196.
  • 5Waplington M,Lumley PJ,Walmsley AD.Incidence of root face alteration after ultrasonic retrograde cavity preparation.Oral Surg Oral Med Oral Pathol Oral Radiol Endod,1997,83(3):387.
  • 6Syngcuk Kim,Endodontic Microsurgery.In:Cohen S,Burns RC,eds.Pathways of pulp.8ed.St Louis:Mosby,1994.713-6.
  • 7Navarre SW,Steiman HR.Root-end fracture during retropreparation:A comparison between zirconirm nitride-coated and stainless steel microsurgical ultrasonic instruments.J Endodon,2002,28(4):330.
  • 8Layton CA,Marshall JG,Morgan LA,et al.Evaluation of cracks associated with ultrasonic root-end preparation.J Endod,1996,22(4):157.
  • 9Morgan LA,Marshall JG.A scanning electron microscopic study of in vivo ultrasonic root-end preparations.J Endod,1999,25(8):567.
  • 10Engel TK.Steimann HR.Preliminary investigation of ultrasonic root end preparation.J Endod,1995,21(9):443.

同被引文献90