摘要 对某钢铁公司炼钢厂扩容后的2号转炉炉壳进行现场温度测试,由测试结果运用有限单元法对炉体进行温度场模拟以及三维热机耦合应力分析,分析炉壳的温度场及应力分布,为转炉炉体的扩容改造与安全性提供了数据参考。 On the basis of the results out of the on-site temperature measurement, the temperature field and stress distribution over the converter shell have been analyzed by using the finite element method for calculation of the thermal-mechanical coupling stress over the revamped converter sell. It can be used as a reference and guideline for converter capacity enlargement and revamp project and converter safety purpose.
出处 《炼钢》 CAS 北大核心 2006年第2期43-45,62,共4页 Steelmaking
关键词 转炉 扩容 热机耦合 安全性 converter volume capacity enlargement thermal-mechanical coupling safety
  • 相关文献

参考文献3

二级参考文献9

  • 1陈家祥.连续铸钢手册[M].冶金工业出版社,1991..
  • 2钱之荣 范广举.耐火材料实用手册[M].冶金工业出版社,1987..
  • 3Brezny B,Chen En-sheng.Effects of co-molded brick on thermonmechanical stresses in BOF lining[A].Steelmaking Conference Proceedings[C].1994.499-504.
  • 4钱之荣 范广举.耐火材料实用手册[M].北京:冶金工业出版社,1987..
  • 5陈家祥.连续铸钢手册[M].北京:冶金工业出版社,1991..
  • 6Neil J Goodman,David Brown.Development of the Hi-Vap BOF cooling system.Iron and Steel Engineer,Nov.1993,52~55
  • 7B.Brezny and EN-Sheng Chen.Effects of co-molded Brick on Thermonmechanical stresses In BOF lining.Steelmaking conference proceedings.1994,499~504
  • 8任学平,章博,邹家祥.大型转炉炉体温度场有限元仿真试验[J].上海金属,2001,23(5):38-41. 被引量:8
  • 9朱益明.高强度镁碳砖的研制[J].上海金属,1991,13(2):28-32. 被引量:10