期刊文献+

焦化塔双能γ射线液位测量 被引量:1

Measurement of liquid level of coke-cracking tower based on dual-energy γ-ray transmission
在线阅读 下载PDF
导出
摘要 介绍了一种用双能γ射线测量焦化塔液位的方法,能同时测量焦化塔的液位和泡沫的高度。通过实时测量的液位曲线和泡沫高度曲线,提高了生产效益,测量周期从原来的23h缩短到16h,消泡剂节省了12%。同时,采用线状放射源和设计高性能的γ能谱仪,提高了测量精度和稳定性,液位测量误差小于4.3%。 A measurement method of liquid level of a coke-cracking tower based on dual-energy γ-ray transmission is presented, Both liquid level and height of foam in a coke-cracking tower have been determined by using the measured real-time curves. It was shown that the productive efficiency was raised, the productive cycle was shortened from 23 h to 16 h, and the defoamer was saved by 12%. Meanwhile, by using rod-like radioactive sources and high performance γ-ray spectrometer, both precision and stability of the measurement were improved, e.g. the measurement error of liquid level was less than 4.3%.
机构地区 佛山大学理学院
出处 《核技术》 EI CAS CSCD 北大核心 2006年第3期225-228,共4页 Nuclear Techniques
基金 广东省自然科学基金(04011642)
关键词 双能γ射线 液位计 线状放射源 焦化塔 Dual-energy γ-ray, Liquid level gauge, Rod-like radioactive source, Coke-cracking tower
  • 相关文献

参考文献6

二级参考文献6

共引文献22

同被引文献6

  • 1王经谨等.核电子学(上)[M].北京:原子能出版社,1985.172.
  • 2Cottini C. et al. A New Method for Analog to Digital Conversion[J]. Nucl Intru & Meth. , 1963, 24 : 241.
  • 3何立民.MCS-51系列单片机应用系统设计-系统配置与接口技术[M].北京:北京航空航天大学出版社,2002:305.
  • 4Buckens P F, Veatch M S. A high performance peak detect & hold circuit for pulse height analysis [J]. IEEE Trans Nucl Sci, 1992. NS39 (4) : 753.
  • 5陈勇,李延国,吴枚.新型高性能脉冲峰值保持电路[J].核电子学与探测技术,1997,17(4):241-246. 被引量:26
  • 6王百鸣,潘志铭,朱明程.新结构高速高精度采样保持放大器的研究[J].微电子学,2003,33(3):173-175. 被引量:6

引证文献1