摘要
采用等效点源法计算结晶器液面计棒状 ̄(137)Cs源的活度分布。为扩展线性响应范围,考虑积累因子的贡献。将按设计方案制作的棒状 ̄(137)Cs源安装在120×120结晶器水套上的冷试验结果表明,测程为110mm,线性响应范围为65mm,在此范围内液面高度测定值的非线性误差小于±1%。
The activity distribution of the rod-like  ̄(137)Cs source in the crystallizer liquidometer is calcu-lated using the equivalent point source method.The build-up factor is considered to extend thelinear response region.The rod-like  ̄(137)Cs source made according to the result of the calculation isplaced on the water jacket of the crystallizer with the dimensions of 120 mm×120 mm,and theresult of the cool experiment shows that the monitoring and the linear response regions are 110mm and 65 mm,respectively.The nonlinear deviation of the level monitoring value within linearregion is less than 1%.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
1994年第4期378-381,共4页
Atomic Energy Science and Technology
关键词
结晶器
液面计
Γ射线源
铯137
Crystallizer Liquidometer Equivalent point source method Rod-like  ̄(137)Cssource