摘要 在酸性介质中.SCN^-能使溴酸钾-溴化钾与罗丹明B反应体系的荧光强度增强,据此建立了测定痕量SCN的新方法。利用固定时间法优化了试剂浓度、反应时间和反应温度。在所选择的实验条件下测定SCN的线性范围为0.80—72ng/mL,方法的检出限为0.33ng/mL,对不同浓度的硫氰根测定其相对标准偏差小于1.0%,并考察了20多种离子和物质的干扰情况。该方法已用于吸烟者和不吸烟者唾液中SCN^-的测定。并对反应机理进行了探讨。 Based on the enhancing effect of SCN^- on the fluorimetric intensity of the reaction of potassium bromide -potassium bromate with rhodamine B, a new kinetic fluorimetric method for the determination of thiocyanate ( SCN^- ) in acid medium was developed. The experimental conditions including the reagent concentration, the reaction temperature and time were optimized at fixed reaction time. The linear range of the calibration curve was 0. 80 - 72 ng/mL SCN^- with a correlation coefficient of 0. 999 1. The detection limit of SCN was 0. 33 ng/mL and the relative standard deviations for 8.0 ng/mL and 64 ng/mL SCN^- were 1.01% and 0. 62% (n = 10), respectively. The effects of common ions and organic compounds on the determination were investigated. This method has been applied to the determination of trace SCN^- in saliva of smokers and non-smokers. The possible reaction mechanism was suggested.
出处 《分析测试学报》 CAS CSCD 北大核心 2006年第1期109-111,共3页 Journal of Instrumental Analysis
基金 河南省自然科学基金资助项目(0511021200) 河南省环境污染控制重点实验室基金资助项目
关键词 荧光动力学 唾液 SCN^- Kinetic fluorimetric method Saliva Thiocyanate
  • 相关文献

参考文献10

  • 1CAI X H, ZHAO Z F. [J]. Anal Chim Acta, 1988, 212(1) : 43 -48.
  • 2ANDERS B B, ELO H H. [J]. Analyst, 1991, 116(6) : 647 -651.
  • 3GEORGE S, SCHENCK J R. [J]. Anal Bio Chem, 1983, 130:416 -419.
  • 4VALDES M G, DIAZ -GARCIA M E. [J]. Crit Rev Anal Chem, 2004, 34(1): 9 -23.
  • 5VAN STADEN J F, BOTHA A. [J]. Anal Chim Acta, 2000, 403(1 -2): 279 -286.
  • 6AMINI M K, RAFI A, GHAEDI M, et al. [J]. Microchem J, 2003, 75(3) : 143 -150.
  • 7GAWARGIOUS Y A, BRODERSEN K, WERNER U, et al. [J]. Anali Di Chimica, 1995, 85( 1-2) : 97 - 104.
  • 8LIU X Y, YUN Z H. [J]. J Chromatogr, A, 1993, 653(2) : 348 -353.
  • 9GONG B L, GONG G Q. [J]. Anal Chim Acta, 19991 394(2-3): 171 -175.
  • 10张贵珠,刘善军,何锡文,史慧明.动力学光度法测定微量Br^-的研究(Ⅰ)[J].分析试验室,1993,12(2):4-7. 被引量:17

二级参考文献1

  • 1王景全,张振森,杜新军.地质样品中卤族元素的离子色谱法测定[J]分析化学,1987(09).

共引文献16

同被引文献114

引证文献8

二级引证文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部