期刊文献+

功能影像设备PET-CT 被引量:9

PET-CT: a functional imaging device
在线阅读 下载PDF
导出
摘要 PET—CT是功能医学影像设备,其成像理论和技术复杂,在临床实际应用过程中,对PET—CT设备和技术的认识尚存在着争论,本文就PET—CT设备相关的技术理论、未来软硬件发展的趋势进行探讨。以期对PET—CT的全面认识和评价。 PET-CT is a functional imaging device with a complicated imaging theory and technique. It attracts some arguments when applied clinically. This paper discusses mainly its technique problems and its prospects in the future.
出处 《医疗卫生装备》 CAS 2005年第12期27-30,共4页 Chinese Medical Equipment Journal
关键词 PET CT 衰减校正 图像融合 PET CT attenuation correction imaging fusion
  • 相关文献

参考文献22

  • 1TBeyer,D.W Townsend,T.M.Blodgett.Dual-modatyPET/CTtomopgraphy for clinicaloncology[J].The Quarterli Journal of Nuclear Medicine,2004,46(1):24-34.
  • 2David W. Townsend, Jonathan PJ. Carney, Jeffrey TYap,et al. PET/CT Today and Tomorrow[J].The Journal of Nuclear Medicine,2004,45:4-13.
  • 3陈盛祖.关于PET/CT与分子影像学[J].中华核医学杂志,2003,23(S1):11-12. 被引量:14
  • 4Jager P L, Slart R H, Corstens F, et al. PET-CT:a matter of opinion?[J].Eur-J-Nucl-Med-Mol-Imaging.2003,30(3):470-471.
  • 5Vogel W V, Oyen oW J, Barentsz,etal. PET/CT:panacea, redundancy,or something i nbetween?[J].J-Nucl-Med,2004,45 (Suppl 1 ): 15-24.
  • 6Lardinois D, Weder W, Hany, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography[J].N-Engl-J-Med, 2003,348(25):2500-2507.
  • 7Kinahan PE, Townsend DW, Beyer T, et al, Attenuation correction for a combined 3DPET/CT scanner[J].Med Plays,1998,25(10):2046-2053.
  • 8Nakamoto Y, Osman M, Cohade C, et al. PET/CT: comparison of qua ntitativetracer uptake between germanium and CT transmission atten uation-correctedimages[J].J-Nucl-Med, 2002,43(9):1137-1143.
  • 9Kamel E M, Burger C, Buck A,et al.Impact ofmetallic dental implants on CT-basedattenua tioncorrection in a combined PET/CT scanner [J].Eur-Radiol, 2003,13(4):724-728.
  • 10D. Visvikis, D.C. Costa, I. Croasdale, et al. CT-based attenuation cor rection in the calculation of semi-quantitative indices of [18F] FDG uptake in PET[J].Eur J Nucl Med, 2003,30:344-353.

二级参考文献3

  • 1D. Visvikis,D. C. Costa,I. Croasdale,A. H. R. Lonn,J. Bomanji,S. Gacinovic,P. J. Ell. CT-based attenuation correction in the calculation of semi-quantitative indices of [18F]FDG uptake in PET[J] 2003,European Journal of Nuclear Medicine and Molecular Imaging(3):344~353
  • 2刘秀珍,孙若鹏,姜玉华.难治性癫痫[J].中国乡村医生,1998,14(2):10-11. 被引量:18
  • 3孙效刚,谭峰,张岳松,樊跃飞,张振江,戴硕,陈继锁,余军武.ECOG评估PET对致痫灶定位的准确性[J].现代康复,2000,4(5):731-731. 被引量:6

共引文献25

同被引文献67

引证文献9

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;