功能MRI的伪影校正方法 被引量:1

A Review of Methods for Correction of Artifacts in Functional MRI
暂未订购
导出
摘要 分析对功能 MRI 数据分析影响较为严重的头部运动伪影、生理运动伪影、血流伪影、ghost 伪影及敏感性伪影的产生机制, 综述现有的伪影校正方法,并提出功能 MRI 伪影校正方法研究的一些新方向。 There are many kinds of artifacts in image series of functional MRI, such as head motion artifacts, physiological motion artifacts, blood flow artifacts, ghost artifacts and susceptibility artifacts. These artifacts, which are unassociated with the neural activities, have so severe affects on the analysis of functional MRI data that they not only reduce the sensibility and reliability of functional MRI, but also make the detecting, locating and visualizing of the functional active regions more complicated. The mechanism and the effect of artifacts in functional MRI are discussed here, the methods of correcting artifacts are reviewed, and research prospects are discussed too.
出处 《中国医疗器械杂志》 CAS 2005年第6期429-434,共6页 Chinese Journal of Medical Instrumentation
基金 国家重点基础研究发展计划资助项目(项目编号:2003CB716102)
关键词 磁共振成像 功能磁共振成像 回波平面成像 伪影 MRI, functional MRI, EPI, artifact
  • 相关文献

参考文献11

  • 1王世杰,罗立民.功能磁共振时间序列图像快速配准方法研究[J].东南大学学报(自然科学版),2003,33(2):211-214. 被引量:2
  • 2Friston K, et al. Movement related effects in fMRI time series. Magn. Reson. Med.1996, 35:346-355
  • 3Jezzard P and Clare S. Sources of distortion in functional MRI data. Human Brain Mapping, 1999, 8:80-85
  • 4Hu X, et al. Retrospective estimation and compensation of physiological fluctuation in functional MRI. Magn. Reson. Med, 1995, 34:210-221
  • 5Ogawa S, et al. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging: a comparison of signal characteristics with a biophysical model. Biophys. J., 1993, 64:803-812
  • 6Buonocore MH et al. Ghost artifact reduction for echo planner imaging using image phase correction. Magn. Reson. Med. 1996, 38:89-100
  • 7Buonocore MH et al. Image-based ghost correction for interleaved EPI. Magn.Reson. Med, 2001, 45:96-108.Kupusamy K, et al. Importance of EKG gating in functional magnetic resonance imaging of human motor cortex. Abs. Soc. Neurosci.1995, p. 1420.
  • 8Reber P J, et al. Correction of off resonance-related distortion in echo planar imaging using EPI-Based field maps. Magn. Rseon. Med. 1998, 39:328-330
  • 9Chen, N., & Wyrwicz, A. M. Removal of intravoxel dephasing in gradient -echo images using a field-map based RF refocusing technique. Magnetic Resonance in Medicine, 1999, 42: 807-812.
  • 10Crelier, G. R., Hoge, R. D., Munger, P., & Pike, G. B. Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions.Magnetic Resonance in Medicine, 1999, 41(1):132-136

二级参考文献6

  • 1[4]Stone H S, Orchard M T, Martucci S A, et al. A fast direct Fourier-based algorithm for subpixel registration of images [J]. IEEE Trans Geoscience and Remote Sensing, 2001, 39(10): 2235-2243.
  • 2[5]Unser M, Aldroubi A, Eden M. B-spline signal processing: PartⅠ- theory[J]. IEEE Trans Signal Processing, 1993, 41(2): 821-832.
  • 3[6]Unser M, Aldroubi A, Eden M. B-spline signal processing: Part Ⅱ- efficient design and applications [J]. IEEE Trans Signal Processing, 1993,41(2): 834-848.
  • 4[1]Thévenaz P, Ruttimann U E, Unser M. A pyramid approach to subpixel registration based on intensity [J]. IEEE Trans Image Processing, 1998,7(1):27-41.
  • 5[2]Kim S P, Su W Y. Subpixel accuracy image registration by spectrum cancellation [A]. In: Proc ICASSP[C]. Minneapolis, MN, 1993. 153-156.
  • 6[3]Shekarforoush H, Berthod M, Zerubia J. Subpixel image registration by estimating the polyphase decomposition of cross power spectrum [A]. In: Comput Vis Pattern Recognit[C]. Los Alamitos, CA: IEEE Computer Society Press, 1996. 532-537.

共引文献1

同被引文献5

  • 1燕树林.全国CT、MR技师上岗培训考试参考资料[M].北京:中华医学会继续教育部,1998.184-188.
  • 2Hashemi RH,Bradley WG,Lisanti CJ 著,尹建忠 译.MRI基础[M].第2版.天津:天津科技翻译出版公司,2004.209-235.
  • 3Aleeci M,Jezzard P.Characterization and reduction of gradient-induced eddy currents in the RF shield of a TEM resonator[J].Magn Reson Med,2002,48(2):404-407.
  • 4Papadakis NG,Martin KM,Pickard JD,et al.Gradient preemphasis calibration in diffution-weighted echo-planar imaging[J].Magn Reson Med,2000,44(4):616-624.
  • 5李晓红 卢光明.颈部磁共振血管造影的伪影及消除方法.中国医学影像技术,1999,15:32-33.

引证文献1

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部