期刊文献+

视觉系统成像质量的评价分析 被引量:2

Analysis of evaluation on imaging quality of visual system
暂未订购
导出
摘要 目前人眼视觉系统成像质量评价的方法有两大类:一类是几何光学的方法,另一类是物理光学的方法。前者是传统的方法,而后者是近来被人们引入的评价视觉系统成像质量新方法。文章通过描述分析两种方法的评价原理,得出在临床与科研使用中,应该根据具体的检查要求选择合适的评价方法。 There are currently two kind of ways to evaluate the quality of visual system imaging: one belongs to geometrical optics, which is the conventional way; the other belongs to physical optics, which is the new way to evaluate the visual imaging. The principal of the two evaluation systems was described and analyzed respectively. The author concluded that the selection of two ways depends on the specific needs in clinic or research work.
作者 金晨晖
出处 《国际眼科杂志》 CAS 2005年第5期1020-1023,共4页 International Eye Science
  • 相关文献

参考文献5

二级参考文献20

  • 1李金海,游光华.新型激光视网膜MTF测定仪的光学设计[J].应用激光,1995,15(1):39-40. 被引量:5
  • 2冯郁芬.用全息光学元件测定视网膜功能的新装置.应用激光,1984,4(1):39-40.
  • 3孙文德.视网膜视觉锐度的激光测定.应用激光,1984,4(1):41-43.
  • 4Werner W,et al.Image properties of spherical as aspheric intraocular lenses[J],Klin Monatsbl Augenheilkd, 1999,214(4) :246 - 250.
  • 5Goodman JW.Introduction to fourier optics[M],London:Mcgraw Hill, 1968.88.
  • 6Canpbell FW, Green DG. Optical and retinal factors affecting visual resolution. J Physics,1965;181:576
  • 7Campbell FW, Gubisch RW. Optical quality of the human eye.J Physics,1966;186:558
  • 8Rushton WAH.Visual adaptation. In: Moses RA ed. Adler's physiology of the eye. 7th ed. St. Louis: The CV Mosby Company,1981:650
  • 9Pelli DG, Robson JG, Wilkins AJ. The design of a new letter chart for measuring contrast sensitivity. Clim Vis Sci,1988;2:187
  • 10Campbell FW. Robson JG. Application of Fourier analysis to the visibility of gratings.J Physvcs,1968;197:551

共引文献49

同被引文献25

  • 1何守志.重视研究人工晶状体个性化选择新趋势[J].中华眼科杂志,2006,42(5):385-386. 被引量:17
  • 2Mutlukan E, Dhillon B, Aspinall P, et al. Low contrast visual acuity changes in human immuno-deficiency virus (HIV) infection[J]. Eye, 1992,6(1) :39-42.
  • 3Regan D, Neima D. Low-contrast letter charts in early diabetic retinopathy, ocular hypertension, glaucoma, and Parkinson's disease[J]. Br J Ophthalmol, 1984,68(12) :885-889.
  • 4Lohmann CP, Fitzke F, O'Brart D, et al. Corneal light scattering and visual performance in myopic individuals with spectacles, contact lenses, or excimer laser photorefractive keratectomy[J]. Am J Ophthalmol, 1993,115(4) :444-453.
  • 5Bailey MD, Walline JJ, Mitchell GL, et al. visual acuity in contact lens wears[J]. Optom Vis Sci,2001,78(10):726-731.
  • 6Brown B, Lovie-Kitchin JE. High and low contrast acuity and clinical contrast sensitivity tested in a normal population[J]. Optom Vis Sci, 1989,66(7) :467-473.
  • 7Hendricks IM, Ruddock KH, Waterfield VA. Spectral sensitivity functions of post-receptoral responses in human vision[J]. J Physiol, 1982,331:17-33.
  • 8Miller D. Optics and refraction[M]. New York:Gower Medical Publishing, 1991.
  • 9Scbwartz SH. Visual perception[M]. USA:Appleton & Lange Publishing, 1999.
  • 10Hong X, Hime baugh N, Thibos LN. On-eye evaluation of optical performance of rigid and soft contact lenses[J]. Opotom Vis Sci,2001,78(12):872-880.

引证文献2

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部