Optimizing the Quadruple-potential Waveform for the Determination of Gentamicin Sulfate by High Performance Liquid Chromatography with Pulsed Electrochemical Detection 被引量:4

Optimizing the Quadruple-potential Waveform for the Determination of Gentamicin Sulfate by High Performance Liquid Chromatography with Pulsed Electrochemical Detection
原文传递
导出
摘要 In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative potential was adopted as a potential for the cleaning of gold working electrode. By this way, the formation of gold oxide resulting from the application of high positive potential during the analyte detection and electrode cleaning was greatly reduced, and therefore, the dissolution and recession of gold working electrode was also reduced. The good condition of gold working electrode achieved by this quadruple-potential waveform can help us to obtain a good reproducibility. In order to acquire signal-to-noise ratio as high as possible, several waveform parameters affecting the detection of gentamicin were carefully selected. The analytical method has been applied to the determination of two real gentamicin samples, and good results with low relative standard deviation not more than 4% were obtained. In this paper, a quadruple-potential waveform was investigated and optimized for the determination of gentamicin by reversed phase ion-pair chromatography. Instead of a relatively high positive potential, a negative potential was adopted as a potential for the cleaning of gold working electrode. By this way, the formation of gold oxide resulting from the application of high positive potential during the analyte detection and electrode cleaning was greatly reduced, and therefore, the dissolution and recession of gold working electrode was also reduced. The good condition of gold working electrode achieved by this quadruple-potential waveform can help us to obtain a good reproducibility. In order to acquire signal-to-noise ratio as high as possible, several waveform parameters affecting the detection of gentamicin were carefully selected. The analytical method has been applied to the determination of two real gentamicin samples, and good results with low relative standard deviation not more than 4% were obtained.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2005年第9期1207-1212,共6页 中国化学(英文版)
基金 Project supported by the Major State Basic Research Development Program (No. 2003CB415001) of China and the National Natural Science Foundation of China (No. 20475060).
关键词 quadruple-potential waveform pulsed electrochemical detection reversed phase ion-pair chromatography GENTAMICIN quadruple-potential waveform, pulsed electrochemical detection, reversed phase ion-pair chromatography, gentamicin
  • 相关文献

同被引文献34

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部