期刊文献+

对比剂浓度及剂量对MSCT髂静脉成像的影响 被引量:3

Impact of concentration and dosage of contrast medium on the image quality of iliac vein on multi-slice spiral CT
暂未订购
导出
摘要 目的:探讨不同对比剂浓度及注射剂量对MSCT髂静脉成像质量的影响。方法:120例受检者按不同对比剂浓度及注射剂量随机分成6组,Ⅰ组(300 mg I/ml,100 ml),Ⅱ组(150 mg I/ml,100 ml),Ⅲa组(100 mg I/ml,150 ml),Ⅲb组(100 mg I/ml,100 ml),Ⅲc组(100 mg I/ml,50 ml),Ⅳ组(50 mg I/ml,100 ml),每组各20例,注射流率均为3.0 ml/s,均在经足注射对比剂后20 s行MSCT扫描。所有扫描数据均进行横断面、MPR、MIP及VR重建,分别测量髂总静脉上端、髂静脉分叉处及髂外静脉下端的CT值,观察对比剂伪影情况,根据图像质量评判标准分别作出评价并进行对比分析。结果:120例受检者均顺利完成MSCT髂静脉增强扫描。髂静脉强化程度随对比剂浓度的升高而升高,而对比剂相关伪影则随对比剂浓度的降低而下降,Ⅲa与Ⅲb组的图像总体质量优于其它组(P<0.05),获得了优质的横断面及三维重建图像,Ⅲa组与Ⅲb组的图像总体质量差异无统计学意义(P>0.05)。结论:经患侧足部浅静脉以3.0 ml/s的流率注射浓度为100 mgI/ml的对比剂100 ml,延迟20 s开始扫描是MSCT髂静脉成像较理想的对比剂注射方案。 Objective:To assess the impact of concentration and dosage of contrast medium on the image quality of iliac vein on MSCT.Methods:120 cases were divided randomly into six groups according to different concentration and dosage of contrast medium injected,including Group Ⅰ(300mg I/ml,100ml),Group Ⅱ(150mg I/ml,100ml),Group Ⅲa(100mg I/ml,150ml),Group Ⅲb(100mg I/ml,100ml),Group Ⅲc(100mg I/ml,50ml)and Group Ⅳ(50mg I/ml,100ml),the injection rate of the contrast medium was 3.0ml/s.MSCT was performed 20s later after ...
出处 《放射学实践》 北大核心 2011年第1期86-89,共4页 Radiologic Practice
基金 杭州市医药卫生科技计划项目(2006B029)
关键词 对比剂 体层摄影术 X线计算机 髂静脉 血管造影术 Contrast medium Tomography X-ray computed Iliac vein Angiography
  • 相关文献

参考文献6

  • 1李天然,钱根年,郑春雨,李铭山.16层螺旋CT静脉血管造影的影像分析[J].临床放射学杂志,2005,24(5):460-461. 被引量:6
  • 2黄美萍,梁长虹,曾辉,刘其顺,张忠林,张金娥,黄飚.多层螺旋CT静脉造影诊断下肢静脉血栓性病变[J].中国医学影像技术,2004,20(3):402-404. 被引量:42
  • 3Prokop M.Multislice CT angiographg. Eur J Rediology . 2000
  • 4Lawler LP,Fishman EK.Pericardial varices: depiction on three-dimensional CT angiography. American Journal of Roentgenology . 2001
  • 5Begemann PGC,Bonacker M,Kemper J,et al.Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography. Journal of Computer Assisted Tomography . 2003
  • 6Rubin G D,Shiau M C,Leung A N,et al.Aorta and iliac arteries: Single versus multiple detector-row spiral CT angiography. Radiology . 2000

二级参考文献13

  • 1[1]Loud PA, Katz DS, Bruce DA,et al. Deep venous thrombosis with suspected pulmonary embolism:detection with combined CT venography and pulmonary angiography[J]. Radiology,2001,219(2):498-502.
  • 2[3]Duwe KM, Shiau M, Budorick NE, et al. Evaluation of the lower extremity veins in patients with suspected pulmonary embolism:a retrospective compararison of helical CT venography and sonography[J].AJR,2000,175(6):1525-1531.
  • 3[4]Line BR. Pathophysiogy and diagnosis of deep venous thrombosis[J]. Seminars in Nuclear Medicine,2001,31(2):90-101.
  • 4[6]Baldt MM, Zontsich T, Stumpflen A, et al. Deep venous thrombosis of lower extremity: efficacy of spiral CT venography compared with conventional venography in diagnosis[J]. Radiology,1996,200(2):423-428.
  • 5[9]Loud PA, Katz DS, Klippenstein DL, et al.Combined CT venography and pulmonary angiography in suspected thromboembolic disease:diagnosis accuracy for deep venous evaluation[J]. AJR,2000,174(1):61-65.
  • 6[10]Maki DD, Kumar N, Nguyen B, et al. Distribution of thrombi in acute lower extremity deep venous thrombosis:implications for sonography and CT and MR venography[J]. AJR,2000,175(5):1299-1301.
  • 7Rubin GD, Shiau MC, Leung AN,et al. Aorta and iliac arteries: single versus multiple detector-row helical CT angiography. Radiology, 2000, 215:670.
  • 8Savastano S, Teso S, Corra S,et al. Multislice CT angiography of the celiac and superior mesenteric arteries: comparison with arteriographic findings. Radiol-Med-(Torino), 2002, 103:456.
  • 9李晓兵,田建明,王培军,王敏杰,萧毅,郝强,左长京,薛宏,范玉兰.多层螺旋CT血管造影在大血管病变术后复查中的应用[J].临床放射学杂志,2001,20(9):674-677. 被引量:21
  • 10王锡明,武乐斌,邵广瑞,李振家,柳橙,周延强.多层螺旋CT成像技术在全身血管造影中的应用[J].中国医学影像技术,2002,18(4):333-334. 被引量:44

共引文献46

同被引文献52

  • 1缪熙音,陈刚,陈文芳,陆海峰,张利军,曾良斌,陆秀良,周建军.64排螺旋CT胰周血管CT成像:不同浓度对比剂的对照研究[J].中国临床医学影像杂志,2010,21(11):830-832. 被引量:11
  • 2李天然,赵春雷,陈自谦,钱根年,李铭山,栗莉,陈蕾蕾.多层螺旋CT直接下肢静脉造影价值初探[J].临床放射学杂志,2006,25(8):772-774. 被引量:26
  • 3李宗生,王兴卉,王洪生,王风云.双向多层螺旋CT下肢静脉造影法的研究和应用[J].实用医学影像杂志,2006,7(4):255-256. 被引量:7
  • 4魏巍巍,刘翠红,许维亮,甘洁,仲海,刘平.16层螺旋CT在下肢动脉闭塞性疾病中的应用价值[J].中国中西医结合影像学杂志,2007,5(2):110-112. 被引量:22
  • 5Kun T, Jakubowski L. Influence of MRI contrast media on hista- mine release from mast cells. Pol J Radiol,2012,77 (3) :19-24.
  • 6Sk6rkowska-Telichowska K, Kosifiska J, Szymczak R, et al. Com- parison and assessment of thyroid morphology and function in in- habitants of lower silesia before and after administration of a sin- gle dose of iodine-containing contrast agent during cardiac inter- vention procedure. Endokrynol Pol,2012,63 (4) :294-299.
  • 7Anghcloiu GO, Hanscheid H, Wen X, et al. Experimental first- pass method for testing and comparing sorbent polymers used in the clearance of iodine contrast materials. Blood Purif, 2012,34 ( 1 ) :34-39.
  • 8Wang J, Qu M, Duan X, et al. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study. Eur Radiol,2012,22(12) :2589-2596.
  • 9Prechtel HW, Verburg FA, Palmowski M, et al. Different intrave- nous contrast media concentrations do not affect clinical assess- ment of 18F-fluorodeoxyglucose positron emission tomography/ computed tomography scans in an intraindividual comparison. In- vest Badiol, 2012,7 ( 9 ) :497 -502.
  • 10Tasaki T, Miura Y, Yamada Y, et al. The hematological and clini- Cal effects of X-ray contrast medium contaminating autologous blood for transfusion purposes. Transfus Apher Sci, 2012,47 (2) : 139-143.

引证文献3

二级引证文献20

相关作者