摘要
提出了一种基于多Agent的广域电流差动保护系统,借助专家系统实现电流差动主、后备保护区的动态在线划分,然后通过各保护Agent间的配合协调实现对整个电网的主、后备电流差动保护。制订了差动保护主后备保护区划分专家系统的知识表示方式和保护区搜索策略,提出了各保护Agent间配合协调的行为规则和通信方式,对该保护系统的通信系统进行了仿真分析,并提出了通信中断等故障时防止差动保护误动的预防性自愈合措施。
A multi-Agent based wide-area current differential protection system is proposed. By means of expert system the dynamic online partitioning of primary and backup protection zones of current differential protection system is implemented, then through the coordination among the Agents of different protections the primary and backup differential current protection for whole power network is realized. The knowledge representation of expert system to partition the primary and backup protection zones of the differential protection and the protection zones searching strategy are worked out, the behavior rule and communication mode for the coordination among the Agents of different protections are presented. The simulation of communication system of this protection system is conducted and the predictive self-healing measures to prevent the maloperation of differential protection are put forward when the communication of protection Agent is interrupted or other failures occur.
出处
《电网技术》
EI
CSCD
北大核心
2005年第14期15-19,共5页
Power System Technology
基金
国家自然科学基金资助项目(50207001)
香港政府大学基金委员会基金项目(HKUGCB.41.37.Q694)
湖南省杰出青年科学基金项目(04JJ1011)
湖南省教育厅重点项目(02A032
03C065)~~
关键词
广域电流差动保护
专家系统
多AGENT
保护区
电力系统
Electric currents
Electric power systems
Electricity
Expert systems
Multi agent systems
Online systems