摘要 为了降低饱和作用,提高单体积三维TOF法静脉血管及动脉小分支的显示能力,我们采用了静脉注射造影剂(Gd-DTPA)的方法缩短血液的T1值,减少饱和作用影响。结果表明,增强MRA不但动脉小分支显示能力提高,而且扫描层面内的重要脑内静脉血管结构显示很清楚,血管的CNR提高。增强MRA短时间内同时显示高分辨率的动静脉血管结构将明显提高MRA的临床应用价值,减少对静脉血管疾病的遗漏。 To overcome the limitation of saturation effects of the 3-D TOF Single volume technique, IV Gd-DTPA contrast enhancement was used to alter the relaxation times of blood, thus augmenting the peripheral arterial and venous aignals. 40 pottients both with and without contrast enhancement of 3-D TOF MRA were evaluated. Only the fast flowing arteries and the large dural sinuse(such as the transverse sinus) could be seen on unenhanced studies owing to the saturation of slowly flowing spins. With contrast enhncement, smaller arieries and many of the important small and large cerebral venous structures were routinely seen with short scanning time. This technique could be ued as a venous secreening examination and mininize the possibilities of miss-diagnosis of venous disorders.
出处 《中国医学影像技术》 CSCD 1994年第2期85-87,共3页 Chinese Journal of Medical Imaging Technology
关键词 造影剂 NMR 成像 脑血管疾病 magnetic resonance angiography (MRA) contrast cerebral blood vessels
  • 相关文献

同被引文献13

  • 1韩鸿宾,沙琳,刘洪东,许峰,边杰,刘溢,杨玉杰.快速多时相减影CE-MRA对头颈部TOF-MRA伪影的矫正[J].中国医学影像技术,2003,19(5):632-635. 被引量:12
  • 2Wetzel SG, Kitsch E, Stock KW, et al. Cerebral veins:comparative study of CT venography with intracranial digital subtraction angiography. AJNR, 1999,20(2):249.
  • 3Wetzel SG, Law M, Lee VS, et al. Imaging of the intracranial venous system with a contrast-enhanced volumetric interpolated examination. Eur Radiol,2003,13(5):1010.
  • 4Lovblad KO, Schneider J, Bassetti C, et al. Fast contrast-enhanced MR whole-brain venography. Neuroradiology, 2002,44(8): 681.
  • 5Liang L, Korogi Y, Sugahara T, et al. Evaluation of tile intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-TOF MR venography anti digital subtraction angiography. AJNR Am J Neuroradiol, 2001,22(3):481.
  • 6Tartaro A, Severini S, Tonni G,et al. Magnetic resonance angiography with gadolinium (Gd-DTPA) versus baseline magnetic resonance angiography in the study of the intracranial circulation.Radiol Med (Torino), 1992,84(5):536
  • 7Yang J J, Hill MD, Morrish WF, et al. Comparison of pre-and post-contrast 3D time-of-flight MR angiography tor the evaluation of distal intracranial branch occlusions in acute ischemic stroke. AJNR Am J Nenroradiol, 2002,23(4):557.
  • 8(美)[C.M.安德森]CharlesM.Anderson等著,祁吉等.临床磁共振血管成像[M]人民卫生出版社,1998.
  • 9丁文学,王明路,杨树源,贺能树,张长林,姚鑫,李崇谦.窦汇区分流形式的临床研究[J].中华神经外科杂志,1998,14(4):243-245. 被引量:5
  • 10刘才兴,吴怀清,杨卫忠.颅内静脉系统窦汇区流向的血管造影分析[J].现代医用影像学,1998,7(5):204-206. 被引量:1

引证文献2

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部