摘要
地铁车站与连接车站的区间形成一个四通八达的网络,气流流向非常复杂。要想在事故区间形成有效通风,单靠设在车站或风井内的大型隧道风机往往达不到通风效果。此时,若能适时采用诱导射流设备,往往能起到事半功倍的效果。结合地铁通风设计,介绍了射流风机和诱导风机系统这两种常用的诱导射流设备的特点、局限性,以及诱导射流设备的选用,探讨诱导射流设备在地铁中的应用。
Mechanical ventilation systems are generally arranged near stations to ensure appropriate temperature or air velocity in subway system.Since stations and tunnels of subway connect with each other and form a network rediating to all directions,the air flow is very complex.Impulse fan and jet fan,with the capability to produce longitudinal airflows, have an advantage over conventional mechanical system, and therefore a better control of tunnel airflows can be achieved by using impulse fan and jet fan.This paper mainly discusses the application of impulse fan and jet fan in subway system.
出处
《城市轨道交通研究》
2005年第2期40-42,共3页
Urban Mass Transit